OPERATION - OPTIONAL FILTER WAND (continued)

OPERATION - OPTIONAL FILTER WAND (continued)

DANGER:

BURN HAZARD

Contact with hot oil will cause severe burns.

Always wear protective clothing and heat resistant gloves when filtering the oil.

WARNING:

 ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD

All servicing requiring access to non-insulated components must be performed by qualified service personnel. DO NOT open any access panel that requires the use of tools. Failure to heed this warning may result in severe electric shock.

IMPORTANT:

Be sure the 3-way valve in the left-rightposition before pressing the FRYER-OFF-FILTER switch to the FILTER position.

FILTERING OIL - NORMAL OPERATION

1.Prepare the filter reservoir pan for filtering.

2.Turn the DRAIN VALVE HANDLE down to open the drain and fill the filter reservoir.

3.Be sure the 3-WAY VALVE HANDLE is in the left-rightposition to direct the pump output to the frypot.

4.Press the FRYER-OFF-FILTER switch to the FILTER position.

5.Filter as per instructions described in Fryer Operation Manual.

NOTE:

If the FRYER-OFF-FILTER switch is pressed to the FILTER position with the 3-way valve handle in the front-to-backposition (wand not installed), the filter pump will stall and then trip on the internal safety. To reset:

1. Turn the 3-way valve to the left-rightposition.

2. Press the FRYER-OFF-FILTER

switch to the OFF position.

3. Wait approximately 3 minutes for the motor to cool.

4. Press the red reset button on the front end of the filter motor until it

“clicks” and locks in.

5. Resume operation.