TROUBLESHOOTING (continued)
SYMPTOM | POSSIBLE CAUSE | SUGGESTED REMEDY |
|
|
|
| Switches not set for filtering | Press power switch (item 1) to FILTER |
|
| Press pump filter switch (item 6) to ON |
|
|
|
Filter pump will not run | Pump overload (item 17) tripped | Reset overload. Press red button until it |
| “clicks” and stays locked in | |
|
| |
|
|
|
| Internal damage (pump overload trips | Contact your Authorized Wells Service |
| frequently) | Agency for repairs |
|
|
|
| Drain valve (item 19) not properly set | Oil level in reservoir must be monitored |
|
| at all times while filtering. Adjust flow by |
|
| opening or closing drain valve |
Filter reservoir overflows |
|
|
Filter leaf surface clogged with crumbs or | Turn drain valve OFF. When bubbles | |
during filter cycle | other cooking debris | begin appearing in frypot turn filter pump |
|
| switch OFF. Carefully slide reservoir out |
|
| 12” and clear surface of filter leaf with |
|
| |
|
| stall reservoir and resume filtering. |
|
|
|
| Filter leaf not properly assembled or not | Reassemble filter leaf. Be sure |
| properly installed | in place, |
Does not filter completely |
| filter leaf is properly installed in reservoir. |
|
| |
| Filter leaf screen damaged | Replace filter leaf |
|
|
|
| Filter leaf | Replace filter leaf |
|
|
|
| Suction tube not seated, allowing air to | When inserting filter reservoir be sure |
| enter system | suction tube is fully seated in suction line |
Filter pump won’t pump, or pumps air |
| receptacle. |
|
| |
when filtering | Suction tube | Replace suction tube |
|
|
|
| Internal damage | Contact your Authorized Wells Service |
|
| Agency for repairs |
|
|
|
|
| NOTE: There are no user serviceable |
|
| components in the fryer. In all cases of |
|
| damage or malfunction, contact your |
|
| Authorized Wells Service Agency for |
|
| repairs. |
|
|
|
371 301098 OpManual for