PRECAUTIONS AND GENERAL INFORMATION (continued)

OPERATIONAL NOTES:

REPLACE PREFILTER and REPLACE FILTER PACK indicator lights provide a timely warning that a system shut-down is imminent.

The actual time between the indicator light coming on and the loss of cooking appliance power will depend upon the cooking conditions.

Anytime a dirty PRE-FILTER is replaced, the system airflow will increase. If the condition of the FILTER PACK is marginal, the REPLACE FILTER PACK light could then come on. If this happens, a fresh FILTER PACK must be installed within a reasonably short time.

Loss of airflow through the old filter pack will soon cause a system shut-down when the airflow falls below minimum vapor capture levels.

KEEP A SPARE FILTER PACK ON HAND.

IMPORTANT: If you decide to “get the most” out of the old filter pack, and continue to use it until a system shut-down happens, it is advisable to have a fresh filter pack readily at hand, and have someone available who is capable of replacing it. Otherwise, you may experience an extended down time, with consequent associated loss of business.

The manufacturer assumes no liability for loss of business due to a system shutdown caused by a dirty pre-filter and/or filter pack (i.e. red SERVICE REQUIRED light is on), when the user fails to have the proper replacement pre-filter and/or filter pack on hand.

The Ventless Cooking System™ hood is designed as part of a WELLS

 

fryer appliance only. No other use of this product is recommended or

 

authorized by the manufacturer or its agents. Wells Mfg. assumes no

 

liability for the use of this equipment with products by any other

 

manufacturer’s, or for use of this equipment with any Wells

Fig. 5 Ventilator

Manufacturing product other than in factory certified applications.

 

Warning

 

Indicators

AGENCY LISTING INFORMATION

This appliance conforms to NSF Standard 4 for sanitation only if installed in accordance with the supplied Installation Instructions

And operated and maintained in accordance with the instructions in this manual.

This appliance is and listed under UL File E146882.

This appliance is evaluated to BOCA, ICBO and SBCCI Building Code Requirements by National Evaluation Service, Inc. (NES) under Report No. NER-620.

E146882 E146882

 

Report No.

STD 4

NER-620

7

Page 9
Image 9
Wells WVF-886 operation manual Precautions and General Information, Agency Listing Information, Operational Notes, Std

WVF-886 specifications

The Wells WVF-886 is a cutting-edge commercial water heater designed to meet the demanding needs of various applications, including restaurants, hotels, and large-scale facilities. This robust unit stands out in the market due to its advanced features, energy efficiency, and durability.

One of the primary characteristics of the WVF-886 is its high-capacity storage system, which ensures a steady supply of hot water even during peak usage times. With a substantial tank size, it can support multiple fixtures simultaneously without compromising performance. The system employs advanced insulation technology to retain heat and minimize energy loss, thus enhancing overall efficiency.

The heater is equipped with a powerful burner system that utilizes direct venting technology. This design enhances combustion efficiency and ensures safe operation by expelling harmful gases outside the building. The WVF-886 features a user-friendly digital display that allows operators to monitor and adjust settings easily, improving convenience and functionality.

Another significant feature of the Wells WVF-886 is its innovative temperature control system. The unit is designed with built-in safety mechanisms that prevent overheating, ensuring not only reliable operation but also adherence to safety regulations. The adjustable thermostat allows for precise temperature settings, tailored to specific operational requirements.

In terms of technology, the WVF-886 integrates smart diagnostics. This system provides real-time feedback on unit performance and alerts operators to any potential issues, reducing downtime and maintenance costs. The unit also supports compatibility with various building management systems, facilitating seamless integration into existing infrastructures.

The Wells WVF-886 is built with high-quality materials for enhanced longevity. Its stainless steel construction is resistant to corrosion, making it ideal for high-demand environments. Furthermore, the unit is designed with easy access for maintenance, allowing technicians to perform routine checks and repairs with efficiency.

Overall, the Wells WVF-886 represents a reliable solution for consistent hot water delivery while prioritizing energy efficiency and safety. Its impressive features and technological advancements make it a top choice for businesses looking to optimize operations without compromising on performance. With this unit, operators can rest assured of meeting their hot water needs effectively and efficiently.