Wells WVF-886 Safety Test System, Fail, OPERATION continued, Danger Burn Hazard, Fire Hazard

Models: WVF-886

1 34
Download 34 pages 59.7 Kb
Page 18
Image 18
SAFETY TEST SYSTEM™

OPERATION (continued)

DANGER: BURN HAZARD

Contact with hot oil will cause severe burns. Allow the fryer to cool before cleaning. Always wear protective clothing and heat resistant gloves when performing this test.

The Safety Test System™ allows a positive test of the function of the temperature limiting (hi-limit) thermostat.

The hi-limit thermostat is factory set for 440ºF (227ºC). It will trip if the oil temperature exceeds this setting, and interrupt power to the heating element.

CAUTION

FIRE HAZARD

Do not hold the TEST switch for more than 2-1/2 minutes. Should the oil temperature not reach the hi-limit setting within 2-1/2 minutes, turn the power switch OFF and contact an Authorized Wells Service Agent for repairs.

IMPORTANT: Use ONLY the test thermometer provided with the fryer .

SAFETY TEST SYSTEM™

1. Fill the frypot to the MIN OIL line. Fresh oil is recommended to mini- mize smoking.

2. Clip the TEST THERMOMETER to a FRYER BASKET. Lower the fryer basket into the oil. Be sure the dial of the test thermometer can be clearly viewed.

3.

Turn the TEMPERATURE

 

 

CONTROL KNOB to the maximum

 

 

setting, then press the POWER

 

 

SWITCH to ON. Allow the oil to heat

Fig. 13 Test Thermometer

 

until the test thermometer reads to

 

 

“START TEST” (350ºF).

 

4.

Press and hold the red TEST SWITCH. The temperature of the

 

oil will rise, and the test thermometer

 

 

will read “TEST ZONE”.

 

IMPORTANT: DO NOT hold the TEST switch for more than 2-1/2 minutes.

When the oil temperature reaches the setting of the hi-limit thermostat, the hi-limit will trip, the red TROUBLE light will glow, and the heating element

will be de-energized.

If the hi-limit thermostat trips while the test thermometer is in the TEST ZONE, the test is complete. The function of the hi-limit thermostat is normal. After oil cools, reset the hi-limit thermostat and resume normal operation.

 

If the test thermometer rises above the TEST

FAIL!

ZONE, the hi-limit is not operating properly.

Release the TEST switch, turn the power switch

 

OFF and contact an Authorized Wells Service Agent

 

for repairs.

5.Reset the hi-limit thermostat:

a.Turn the power switch OFF

b.Allow the oil to cool

c.Press the red button on the back of the element head until it “clicks” and stays in.

6.Remove, clean and store the test thermometer.

Set the temperature control knob to the normal operating temperature. Turn the power switch ON and resume normal operation.

16

Page 18
Image 18
Wells WVF-886 Safety Test System, Fail, OPERATION continued, Danger Burn Hazard, Fire Hazard, Test Thermometer