FEATURES & OPERATING CONTROLS (continued)

 

 

FEATURES & OPERATING CONTROLS (continued)

 

 

 

ITEM

DESCRIPTION

COMMENT

VENTILATOR SECTION

 

1.

NAMEPLATE

Lists Manufacturer, Model and Serial Number information.

 

 

Also lists electrical specifications.

a6.

FIRE SUPPRESSION AGENT

Container for Ansulex™ Low-pH liquid fire suppression liquid.

 

TANK (1.5 gal.)

 

8.

ADJUSTABLE (FRONT) LEG

Allows the unit to be leveled.

9.

RIGID (REAR) CASTER

Allows the unit to be easily positioned by lifting the front of the unit slightly.

a10.

MANUAL PULL STATION

Provides a means of manual activation of the fire suppression system.

 

 

PULL ONLY IN CASE OF FIRE!

a11.

FUSIBLE LINKS

Automatically activates fire suppression system in the event of fire in the fryer.

12.

LOWER REAR ACCESS PANEL

Allows access to Ansul® fire suppression agent tank (a6) and controls also

 

 

access to main power contactor (41).

a15.

DISCHARGE NOZZLE

Fire suppression media discharges here (2 places).

16.

GREASE BAFFLE

Extracts and drains most grease and moisture from the air flow.

18.

PRE-FILTER ASSEMBLY

Comprises the PRE-FILTER FRAME and a replaceable

 

 

PRE-FILTER. Stops larger particles of grease from reaching the FILTER

 

 

PACK for reduced maintenance costs.

19.

HEPA/CHARCOAL FILTER PACK

Stops most grease and smoke particles. Also assists in some cooking odor

 

 

removal.

22.

GREASE CUP

Collects grease/moisture drained from grease trough (23).

23.

GREASE TROUGH

Directs grease/moisture removed by grease baffle to grease cup.

28.

VENTILATOR EXHAUST DUCT

Exit point for ventilator airflow - on top left rear of unit.

 

 

DO NOT BLOCK

a31.

STATUS INDICATOR

Displays status of fire suppression system (COCKED - FIRED). If FIRED, a

 

 

buzzer will sound continuously.

38.

POWER CORD (WHEN PROVIDED)

6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).

40.

WARMER RELAY

Provides power to roll warmer section. Energized at all times except during fire

 

 

safety shut-down.

41.

POWER CONTACTOR

Energizes fryer only while ventilator section is sensed as operational.

42.

BUILDING FIRE ALARM RELAY

Reports fire alarm condition to building fire management system.

43.

GROUND LUG

Ground wire of power cord connects here.

44.

INTERLOCK TERMINAL

Provides connection for shut-down control by building fire management system.

53.

FILTER INTERLOCK SWITCHES

Proper installation of grease baffle and filter pack close these switches in

 

 

ventilator sensor circuit.

56.

VENTILATOR FAN

Provides air movement for ventilation.

VENTILATOR CONTROL AND INDICATOR PANEL

V1

POWER SWITCH

Energizes blower motor. If, after 10 seconds, proper conditions are met,

 

 

appliance is energized.

V2

POWER ON INDICATOR

GREEN. Glows when POWER switch is ON.

V3

CHECK FILTERS ALARM

AMBER. Glows if one or more filters are out of position. Check all filters and

 

INDICATOR

baffles for proper installation.

V4*

REPLACE PREFILTER ALARM

AMBER. Glows when PREFILTER is approaching the end of its service life and

 

INDICATOR

must soon be replaced.

V5*

REPLACE FILTER PACK ALARM

AMBER. Glows when FILTER PACK is approaching the end of its service life

 

INDICATOR

and must soon be replaced.

V6*

SERVICE REQUIRED ALARM

RED. Glows when PREFILTER and/or FILTER PACK has reached the end of

 

INDICATOR

its service life and is too loaded to allow sufficient air flow. Filter MUST be

 

 

replaced. Appliance is SHUT DOWN until expended filters are replaced.

*See PRECAUTIONS & GENERAL INFORMATION, pages 6 & 7 for special procedures regarding prefilters and filter packs.