| FEATURES & OPERATING CONTROLS (continued) |
|
|
|
ITEM | DESCRIPTION | COMMENT |
VENTILATOR SECTION |
| |
1. | NAMEPLATE | Lists Manufacturer, Model and Serial Number information. |
|
| Also lists electrical specifications. |
a6. | FIRE SUPPRESSION AGENT | Container for Ansulex™ |
| TANK (1.5 gal.) |
|
8. | ADJUSTABLE (FRONT) LEG | Allows the unit to be leveled. |
9. | RIGID (REAR) CASTER | Allows the unit to be easily positioned by lifting the front of the unit slightly. |
a10. | MANUAL PULL STATION | Provides a means of manual activation of the fire suppression system. |
|
| PULL ONLY IN CASE OF FIRE! |
a11. | FUSIBLE LINKS | Automatically activates fire suppression system in the event of fire in the fryer. |
12. | LOWER REAR ACCESS PANEL | Allows access to Ansul® fire suppression agent tank (a6) and controls also |
|
| access to main power contactor (41). |
a15. | DISCHARGE NOZZLE | Fire suppression media discharges here (2 places). |
16. | GREASE BAFFLE | Extracts and drains most grease and moisture from the air flow. |
18. | Comprises the | |
|
| |
|
| PACK for reduced maintenance costs. |
19. | HEPA/CHARCOAL FILTER PACK | Stops most grease and smoke particles. Also assists in some cooking odor |
|
| removal. |
22. | GREASE CUP | Collects grease/moisture drained from grease trough (23). |
23. | GREASE TROUGH | Directs grease/moisture removed by grease baffle to grease cup. |
28. | VENTILATOR EXHAUST DUCT | Exit point for ventilator airflow - on top left rear of unit. |
|
| DO NOT BLOCK |
a31. | STATUS INDICATOR | Displays status of fire suppression system (COCKED - FIRED). If FIRED, a |
|
| buzzer will sound continuously. |
38. | POWER CORD (WHEN PROVIDED) | 6’ cord and cap. Plug for NEMA |
40. | WARMER RELAY | Provides power to roll warmer section. Energized at all times except during fire |
|
| safety |
41. | POWER CONTACTOR | Energizes fryer only while ventilator section is sensed as operational. |
42. | BUILDING FIRE ALARM RELAY | Reports fire alarm condition to building fire management system. |
43. | GROUND LUG | Ground wire of power cord connects here. |
44. | INTERLOCK TERMINAL | Provides connection for |
53. | FILTER INTERLOCK SWITCHES | Proper installation of grease baffle and filter pack close these switches in |
|
| ventilator sensor circuit. |
56. | VENTILATOR FAN | Provides air movement for ventilation. |
VENTILATOR CONTROL AND INDICATOR PANEL | ||
V1 | POWER SWITCH | Energizes blower motor. If, after 10 seconds, proper conditions are met, |
|
| appliance is energized. |
V2 | POWER ON INDICATOR | GREEN. Glows when POWER switch is ON. |
V3 | CHECK FILTERS ALARM | AMBER. Glows if one or more filters are out of position. Check all filters and |
| INDICATOR | baffles for proper installation. |
V4* | REPLACE PREFILTER ALARM | AMBER. Glows when PREFILTER is approaching the end of its service life and |
| INDICATOR | must soon be replaced. |
V5* | REPLACE FILTER PACK ALARM | AMBER. Glows when FILTER PACK is approaching the end of its service life |
| INDICATOR | and must soon be replaced. |
V6* | SERVICE REQUIRED ALARM | RED. Glows when PREFILTER and/or FILTER PACK has reached the end of |
| INDICATOR | its service life and is too loaded to allow sufficient air flow. Filter MUST be |
|
| replaced. Appliance is SHUT DOWN until expended filters are replaced. |
*See PRECAUTIONS & GENERAL INFORMATION, pages 6 & 7 for special procedures regarding prefilters and filter packs.
3