VENTILATOR OPERATION

BE SURE BOTH FRYER SWITCHES ARE OFF.

1.Press the VENTILATOR POWER switch to ON. The green VENTILATOR POWER light will glow and the blower fan will start. After a short time, if all filters are sensed as being in position and not clogged, the cooktop will be energized. The roll warmer is energized at all times.

During normal operation, the VENTILATOR POWER light will be the only light glowing on the upper control panel.

2.If the amber CHECK FILTER light glows, one or more filter elements is out of position. Check the GREASE BAFFLE, PRE-FILTER and FILTER PACK for proper installation in their respective positions. Grease baffle and filter pack position are sensed by mechanical switches. Pre-filter position is sensed by a vacuum switch.

3.When the amber REPLACE PRE-FILTERlight glows, the pre-filter is nearing the end of its service life. Replace the disposable

PRE-FILTER ELEMENT.

4.When the amber REPLACE FILTER PACK light illuminates, the HEPA / Charcoal filter pack is nearing the end of its service life. Replace the FILTER PACK.

Note: The REPLACE PRE-FILTER and REPLACE FILTER PACK lights are a warning that the indicated filter is near the end of its service life. The appliance will continue to operate for a period of time after the light glows to allow continued operation through a peak period. However, the indicated filters must be replaced within a reasonably short time period or they will clog and shut down electrical power to the cooktop. The ventilator blower will continue to run.

5.When the red SERVICE REQUIRED light glows, either the pre-filter or filter pack (or both) is clogged and can no longer pass sufficient air to allow further operation. The ventilator fan continues to run, but the cooktop is shut down until the underlying clogged filter situation has been corrected. This can occur when neither CHANGE...FILTER indicator light is lit, if both pre-filter and filter pack are marginal. Replacing both the pre-filter and the filter pack will remedy the situation.

Note: replacing the pre-filter, even though not very dirty, will often extend the service life of the more expensive filter pack.

Reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

6.A failure of incoming electrical power will cause a shut down of the unit. After power is restored, reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

OPERATION

CAUTION:

HOT SURFACE

Exposed surfaces can be hot to the touch and may cause burns.

Fig. 9 Ventilator Indicator and Warning Lights

13

Page 15
Image 15
Wells WVF-886 operation manual Ventilator Operation, Be Sure Both Fryer Switches are OFF, PRE-FILTER Element, HOT Surface

WVF-886 specifications

The Wells WVF-886 is a cutting-edge commercial water heater designed to meet the demanding needs of various applications, including restaurants, hotels, and large-scale facilities. This robust unit stands out in the market due to its advanced features, energy efficiency, and durability.

One of the primary characteristics of the WVF-886 is its high-capacity storage system, which ensures a steady supply of hot water even during peak usage times. With a substantial tank size, it can support multiple fixtures simultaneously without compromising performance. The system employs advanced insulation technology to retain heat and minimize energy loss, thus enhancing overall efficiency.

The heater is equipped with a powerful burner system that utilizes direct venting technology. This design enhances combustion efficiency and ensures safe operation by expelling harmful gases outside the building. The WVF-886 features a user-friendly digital display that allows operators to monitor and adjust settings easily, improving convenience and functionality.

Another significant feature of the Wells WVF-886 is its innovative temperature control system. The unit is designed with built-in safety mechanisms that prevent overheating, ensuring not only reliable operation but also adherence to safety regulations. The adjustable thermostat allows for precise temperature settings, tailored to specific operational requirements.

In terms of technology, the WVF-886 integrates smart diagnostics. This system provides real-time feedback on unit performance and alerts operators to any potential issues, reducing downtime and maintenance costs. The unit also supports compatibility with various building management systems, facilitating seamless integration into existing infrastructures.

The Wells WVF-886 is built with high-quality materials for enhanced longevity. Its stainless steel construction is resistant to corrosion, making it ideal for high-demand environments. Furthermore, the unit is designed with easy access for maintenance, allowing technicians to perform routine checks and repairs with efficiency.

Overall, the Wells WVF-886 represents a reliable solution for consistent hot water delivery while prioritizing energy efficiency and safety. Its impressive features and technological advancements make it a top choice for businesses looking to optimize operations without compromising on performance. With this unit, operators can rest assured of meeting their hot water needs effectively and efficiently.