PRECAUTIONS AND GENERAL INFORMATION

DANGER:BURN HAZARD

Contact with hot oil will cause severe burns. Always wear protective clothing and heat resistant gloves when operating the fryer or filtering the oil.

WARNING: ELECTRIC SHOCK HAZARD

All servicing requiring access to non-insulated components must be performed by qualified service personnel. DO NOT open any access panel that requires the use of tools. Failure to heed this warning may result in severe electric shock.

CAUTION: BURN HAZARD

Contact with hot oil may cause burns. DO NOT fill fryer beyond MAX OIL line on frypot. For disposal of oil use only a container specifically designed for the disposal of hot oil. DO NOT fill hot oil disposal container beyond MAX OIL line.

CAUTION:

RISK OF

DAMAGE

DO NOT connect or energize this appliance until all installation instructions are read and followed. Damage to the appliance will result if these instructions are not followed.

NOTE: This Ventless Cooking System™ is designed to help reduce odor emissions, but will not completely eliminate cooking odors. Air exchange at the installation site must comply with the requirements of the local jurisdictional authority. To ensure that odors do not build-up, recommended minimum air exchange is

300 - 400 cfm of outside air into and out of the area where the unit is used.

IMPORTANT:

DO NOT submerge pre-filter or filter pack in water.

NOTE: Fire suppression system and all associated components must only be serviced by an authorized Ansul® Distributor. All setup, charging, repair and/or adjustment of the fire suppression system must be performed by an Authorized Ansul® Distributor ONLY.

IMPORTANT: If a remote pull station is installed, both rear casters (9) must be replaced with legs to deter moving the unit. MOVING AN APPLIANCE WITH A REMOTE PULL STATION WILL DISCHARGE THE FIRE SUPPRESSION SYSTEM.

This appliance is for use in commercial establishments only.

This appliance is intended to prepare food for human consumption. No other use is authorized by the manufacturer or its agents.

Operators of this appliance must be familiar with the appliance use, limitations and associated restrictions. Operating instructions must be read and understood by all persons using or installing this appliance.

Cleanliness of this appliance is essential to good sanitation. Read and follow all included cleaning instructions and schedules to ensure the safety of the food product.

Disconnect this appliance from electrical power before performing any maintenance or servicing.

Do not splash or pour water on, in or over any exposed element, control, control panel or wiring.

The technical content of this manual, including any wiring diagrams, schematics, parts breakdown illustrations and/or adjustment procedures, is intended for use by qualified technical personnel.

Any procedure which requires the use of tools must be performed by a qualified technician.

This manual is considered to be a permanent part of the appliance. This manual and all supplied instructions, diagrams, schematics, parts breakdown illustrations, notices and labels must remain with the appliance if it is sold or moved to another location.

This appliance is made in the USA. Unless otherwise noted, this appliance has American sizes on all hardware.

6

Page 8
Image 8
Wells WVF-886 operation manual Precautions and General Information, Risk Damage

WVF-886 specifications

The Wells WVF-886 is a cutting-edge commercial water heater designed to meet the demanding needs of various applications, including restaurants, hotels, and large-scale facilities. This robust unit stands out in the market due to its advanced features, energy efficiency, and durability.

One of the primary characteristics of the WVF-886 is its high-capacity storage system, which ensures a steady supply of hot water even during peak usage times. With a substantial tank size, it can support multiple fixtures simultaneously without compromising performance. The system employs advanced insulation technology to retain heat and minimize energy loss, thus enhancing overall efficiency.

The heater is equipped with a powerful burner system that utilizes direct venting technology. This design enhances combustion efficiency and ensures safe operation by expelling harmful gases outside the building. The WVF-886 features a user-friendly digital display that allows operators to monitor and adjust settings easily, improving convenience and functionality.

Another significant feature of the Wells WVF-886 is its innovative temperature control system. The unit is designed with built-in safety mechanisms that prevent overheating, ensuring not only reliable operation but also adherence to safety regulations. The adjustable thermostat allows for precise temperature settings, tailored to specific operational requirements.

In terms of technology, the WVF-886 integrates smart diagnostics. This system provides real-time feedback on unit performance and alerts operators to any potential issues, reducing downtime and maintenance costs. The unit also supports compatibility with various building management systems, facilitating seamless integration into existing infrastructures.

The Wells WVF-886 is built with high-quality materials for enhanced longevity. Its stainless steel construction is resistant to corrosion, making it ideal for high-demand environments. Furthermore, the unit is designed with easy access for maintenance, allowing technicians to perform routine checks and repairs with efficiency.

Overall, the Wells WVF-886 represents a reliable solution for consistent hot water delivery while prioritizing energy efficiency and safety. Its impressive features and technological advancements make it a top choice for businesses looking to optimize operations without compromising on performance. With this unit, operators can rest assured of meeting their hot water needs effectively and efficiently.