FEATURES & OPERATING CONTROLS (continued)

 

 

FEATURES & OPERATING CONTROLS (continued)

 

 

VENTILATOR SECTION

 

ITEM

DESCRIPTION

COMMENT

1.

NAMEPLATE

Gives Manufacturer, Model and Serial Number information.

 

 

Also lists electrical specifications.

a6.

FIRE SUPPRESSION

Container for Ansulex™ Low-pH liquid fire suppression liquid.

 

AGENT TANK (1.5 gal.)

 

8.

ADJUSTABLE (FRONT) LEG

Allows the unit to be leveled.

9.

RIGID (REAR) CASTER

Allows the unit to be easily positioned by lifting the front of the unit

 

 

slightly.

a10.

MANUAL PULL STATION

Provides a means of manual activation of the fire suppression system.

 

 

PULL ONLY IN CASE OF FIRE!

a11.

FUSIBLE LINKS

Automatically activates fire suppression system in the event of fire on

 

 

the cooktop.

12.

LOWER REAR ACCESS

Allows access to Ansul® fire suppression agent tank (a6) and controls

 

PANEL

also access to main power contactor (41).

a15.

DISCHARGE NOZZLE

Fire suppression media discharges here (2 places).

16.

GREASE BAFFLE

Extracts and drains most grease and moisture from the air flow.

18.

PRE-FILTER ASSEMBLY

Comprises the PRE-FILTER FRAME and a replaceable

 

 

PRE-FILTER. Stops larger particles of grease from reaching the

 

 

FILTER PACK for reduced maintenance costs.

19.

HEPA/CHARCOAL FILTER

Stops most grease and smoke particles. Also assists in some cooking

 

PACK

odor removal.

22.

GREASE CUP

Collects grease/moisture drained from grease trough (23).

23.

GREASE TROUGH

Directs grease/moisture removed by grease baffle to grease cup.

28.

VENTILATOR EXHAUST

Exit point for ventilator airflow - on top left rear of unit.

 

DUCT

DO NOT BLOCK

a31.

STATUS INDICATOR

Displays status of fire suppression system (COCKED - FIRED) If

 

 

FIRED, a buzzer will sound continuously.

38.

POWER CORD

6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).

40.

FUSES

Provide over-current protection of cooking appliance.

41.

POWER CONTACTOR

Energizes cooktop only while ventilator section is sensed as

 

 

operational.

42.

BUILDING FIRE ALARM

Reports fire alarm condition to building fire management system.

 

RELAY

 

43.

GROUND LUG

Ground wire of power cord connects here.

44.

INTERLOCK TERMINAL

Provides connection for shut-down control by building fire

 

 

management system.

53.

FILTER INTERLOCK

Proper installation of grease baffle and filter pack close these switches

 

SWITCHES

in ventilator sensor circuit. Provides air movement for ventilation.

56.

VENTILATOR FAN

Provides air movement for ventilation.

58.

SIDE SPACERS

Maintain required 6: spacing from combustible surfaces.

70.

COOLING FAN

Provides cooling for cooktop controls.

3

Page 5
Image 5