Troubleshooting Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.
in).While in Service Mode follow chart to check respective function.
•When the “Rotary Cycle Selector” is set to “Super Wash” and the “Rotary Cycle Selector” is pressed, the door position will be displayed: “OP” if open, “CL” if closed.
•When the “Rotary Cycle Selector” is set to
“Normal” and the “Rotary Cycle Selector” is pressed, the Lock position will be displayed: “UL” if unlocked, “LO” if locked.
•When the “Rotary Cycle Selector” is set to
“Whites ”and the “Rotary Cycle Selector” is
pressed, the High water level will be displayed:
•When the “Rotary Cycle Selector” is set to “Wrinkle Control” and the “Rotary Cycle Selector” is pressed, the Medium water level will be displayed:
•When the “Rotary Cycle Selector” is set to
“Colors” and the “Rotary Cycle Selector” is pressed, the Low water level will be displayed: “_0” if below level, “_1” if above level. The Low water level is defined as the reset water level.
•When the “Rotary Cycle Selector” is set to “Hand Wash” and the “Rotary Cycle Selector” is pressed, the level of Tub unbalance will be displayed: “UC” if balanced, “UO” if unbalanced. “U0” will be displayed during the time when the machine is correcting for the unbalance; e.g. slowing down to redistribute the load or to get to a lower spin speed. Once the situation has been corrected (i.e. the load has begun tumbling or the lower speed has resulted in an acceptable amount of balance); “UC” will once again be displayed.
•When the “Delay” switch pad is pressed, the water temperature will be displayed in Degrees F.
•When the “Rotary Cycle Selector” is set to
“Delicates” and the “Rotary Cycle Selector” is pressed, the water temperature will be displayed in degrees C (Celsius).
While in Service Mode follow chart to check respective function.
Selection | Function | Display |
Rotary cycle | Door position | “OP” or “CL” |
selector set to |
|
|
Super Wash. Press |
|
|
Rotary Selector |
|
|
Knob. |
|
|
Rotary cycle | Lock state | “UL” or “LO” |
selector set to |
|
|
Normal. Press |
|
|
Rotary Selector |
|
|
Knob. |
|
|
Rotary cycle | High water | |
selector set to | level | level. |
Whites. Press |
| |
| above level. | |
Rotary Selector |
| |
|
| |
Knob. |
|
|
Rotary cycle | Medium | |
selector set to | water level | level. |
Wrinkle Control. |
| |
| above level. | |
Press Rotary |
| |
|
| |
Selector Knob. |
|
|
Rotary cycle | Low water | “_0” if below |
selector set to | level | level. “_1” if |
Colors. Press |
| above level. |
Rotary Selector |
|
|
Knob. |
|
|
Rotary cycle | Tub balance | “UC” Balanced |
selector set to |
| “UO” |
Hand Wash. Press |
| Unbalanced |
Rotary Selector |
|
|
Knob. |
|
|
Press Delay switch | Water | Degrees F |
pad. | temperature |
|
Rotary cycle | Water | Degrees C |
selector set to | temperature |
|
Delicates. Press |
|
|
Rotary Selector |
|
|
Knob. |
|
|
Board Output Test
While in Service Mode, pressing the Spin
Speed key will begin the Board Output Test.
This test turns on a specified output after a key press. Pressing the Spin Speed key again cancels the test. Only one output can be “on” at any
time. All outputs will be turned off after five (5) minutes of inactivity.
While in Service Mode follow to check respective function.
•When the “Rotary Cycle Selector” is set to “Super Wash” and the “Rotary Cycle
16 | 2 | 16025909 Rev. 0 | ©2005 Maytag Services |