Service Hints
If your furnace fails to work right, you may avoid inconvenience and the cost of a service call by checking the following points before you call for service.
FOR | YOUR SAFETY |
| FOR YOUR SAFETY |
Do not store or use gasoline | If you smell gas: | ||
or other | flammable vapors and | 1. | Open windows. |
liquids in the vicinity of this or any | 2. | Don't touch electrical. | |
other appliance | 3. | Extinguish any open flame. | |
|
| 4. | Immediatelycallyourgassupplier. |
POSSIBLE | CAUSE | WHAT TO DO | |
If your furnace is not heating or not giving enough heat | |||
Thermostat | is not set correctly. | Reset thermostat to desired setting. | |
Pilot | is out. |
| Check pilot. Relight if necessary follow- |
|
|
| ing instructions for "Operating Your |
|
|
| Furnace". |
Pilot | is on | but burner won't come | If gas valve is set at other than "On" |
on. |
|
| furnace will not operate. Shut furnace |
2203612 NAT
2203622 NAT
3003612 NAT
3003622 NAT
1403611 LPG 1403621LPG 2203611LPG 2203621LPG 3003611LPG 3003621LPG
NOTE: CANADIAN MODEL NUMBERS THIRD DIGIT FROM LEFT TO BE:
1FOR BASIC ALTITUDE
2FOR HIGH ALTITUDE EXAMPLE:
MODEL 1403612 BECOMES 1413612
OR BECOMES 1423612
Burner is not operating properly.
Air flow restricted
Pilot goes out time after time
Pilot and burner access door not closed properly.
If burner is noisy
Gas input amount is incorrect.
Too much primary air.
If blower does not run
Blower not connected to electric power.
If blower motor is noisy
Blower dirty. Blower wheel bent.
down and following instructions for relighting in "Operating Your Furnace" section.
Check flame. If it is yellow, the burner
is not getting enough air. Or if flame is blue and noisy and seems to lift off the
burner, the burner is getting too much air. See "Checks and Adjustments", page 14.
Check that doors, drapes or furniture are not blocking louvers.
Locate vent outlet blockage and clean. Check the door. See section on
"Operating Your Furnace" beginning on page 15.
Contact Williams Service Department. Contact Williams Service Department.
Replace fuse.
Connect to electric power.
Tighten screws.
Clean blower wheel.
Straighten or replace.
See troubleshooting section for more detailed information.
How to Order Repair Parts
When ordering repair parts, always give the following information:
1.MODELNUMBER
2.MFG.DATECODE
3.PART NUMBER
4.PART DESCRIPTION
All parts listed herein may be ordered from your equip- ment supplier.
The Model Number of your Williams wall furnace will be found on the rating plate near gas valve, inside control
compartment.
WILLIAMS | FURNACE | COMPANY | MANUFACTURED | |
225 | Acacia Street | IN THE | U.S.A. | |
Colton, | CA 92324 | USA | Established 1916 | |
(909) | FAX: (909) | |||
© 1997 The Williams Furnace Company Rev. 5/97 | Printed in U.S.A. |
| P322256 |