FOR YOUR SAFETY, READ BEFORE LIGHTING
WILLIAMS GAS CONTROL VALVE P121200 & P171600
I WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A, This appliance has a pilot which must be lighted by hand, When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell around the appliance area
for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electric switch; do not use any phone in your building,
•Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
•If you cannot reach your gas supplier, call the fire department.
C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified serv- ice technician. Force or attempted repair may result in a fire or explosion.
O.Do not usa this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the
control system and any gas control which has been under water.
OPERATING INSTRUCTIONS
1.STOPI Read the safety information above.
2.Turn off all electric power to the appliance (if applicable).
3.Set the thermostat to lowest setting.
4.Open control access panel,
5.Push in gas control knob slightly and turn
clockwise _ to "OFF."
@
IN "OFF" POSITION
; []i_,l[]0[]a
i
I@@
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed in slightly. Do not force.
6.Wait five (5) minutes to clear out any gas, then smell for
gas, including near the floor. If you then smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.
7.Loosen wingnut and open the pilot observation door (if equipped).
8.Find
|
|
|
|
|
| GENERATOR | {I |
9. | Push | in | gas | control |
| __..._ _ _ | |
| knob | slightly | and turn |
| |||
| counterclockwise | _ |
| PILOT | |||
| to "PILOT." |
|
|
| |||
10. | Push | in | control | knob | all the way and | BURNER | |
| hold | in. | Immediately | light the pilot. |
|
Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and It will pop back up. Pilot should remain lit. If It goes out, repeat steps 5 through 10,
•If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
•If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.
11.Close pilot observation door, tighten wingnut (if equipped).
12.Turn gas control knob counterclockwise _ to "ON",
13.Close control access panel.
14.Turn on all electric power to the appliance (if applicable).
15.Set thermostat to desired setting.
TO TURN OFF GAS TO APPLIANCE
1.Set the thermostat to lowest setting.
2.Turn off all electric power to the appliance if service is to be performed (if applicable).
3.Open control access panel.
4.From "ON" position, depress and turn gas control knob clockwise _ to "OFF" position. Do not force.
5.Close control access panel.
WARNING: DUE TO HIGH SURFACE TEMPERATURES
IMPORTANT: KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
CONNECTION WIRING DIAGRAM FOR WALL THERMOSTAT MODELS
THERMOSTAT
LAc ,-,I
/I
LEGEND
--FACTORY WIRED LOW VOLTAGE SCREW "FERMINAL LOW VOLTAGE
NOTE: if any of the odglnal wire as supplied with the appliance has to be replased, use only 18 Ga., 4/64 insulaton, 105o C. AWM copper wire or its equivalent.