Please read our instructions before you install and use your furnace. This will help you obtain the full value from this furnace. It could help you avoid needless service costs, if the answer to the problem is found within this instruction manual.

Basic Description

Your direct vent wall furnace is shipped ready to install

against an exterior wall up to 9 inches thick. For walls greater than 9 inches, and up to 24 inches thick, use an optional VENT EXTENSION KIT listed under OPTIONAL ACCESSORIES.

The furnace may burn either Natural or L.R Gas, depend- ing on the model you have purchased.

No electric power is required unless furnace is equipped with an optional blower accessory.

Always consult your local heating or plumbing inspector, building department or gas utility company regarding

regulations, codes or ordinances which apply to the in- stallation of a direct vent furnace.

The sealed combustion system draws combustion air directly from outdoors into the combustion chamber and combustion gases are discharged directly to the outdoors through tubes mounted to the rear of the furnace.

The furnace heat exchanger is built of heavy gauge steel treated for corrosion resistance.

The furnace cabinet is also constructed of heavy gauge steel and has an enamel paint finish.

The furnace controls are located behind an access door

on the lower front of the furnace. All models are equipped with American Gas Association and Canadian Gas

Association listed gas valves and pilots.

MODELS 1403611, 1403612, 2203611, 2203612, 3003611 and 3003612 are equipped with a built-in thermostat.

MODELS 1403621, 1403622, 2203621, 2203622, 3003621 and 3003622 are equipped with a wall thermostat.

Optional Accessories

MODELS: 1403611; 1403612; 1403621; 1403622

For walls greater than 9 inches thick and up to 24 inches thick, use one of the following Vent Extension Kits:

KIT NUMBER

WALL THICKNESS

9304

9 inches to 15 inches

9303

15 inches to 24 inches

MODELS: 2203611; 2203612; 2203621; 2203622 3003611 ; 3003612; 3003621 ; 3003622

For walls greater than 9 inches thick and up to 24 inches thick, use one of the following Vent Extension Kits:

KIT NUMBER

WALL THICKNESS

9301

9

inches

to 15

inches

9302

15 inches

to 24

inches

 

(220 model series only)

9303

15

inches

to 24

inches

(140 (or) 300 model series)

MODELS: 2203611; 2203612; 2203621; 2203622 3003611; 3003612; 3003621; 3003622

To increase circulation of warmed air within the heated space, you may use Blower Accessory Kit 2302, which is equipped with a two-speed fan and automatic fan switch.

ALL MODELS

For walls less than 41/2 inches thick, a thin Wall Collar Kit

9307 may be used to increase wall thickness if wood strips are undesirable.

ALL MODELS: Decorator Face Panel Colors

Various Face Panel colors may be used on all models. All are constructed of heavy gauge steel with your choice of colored enamel paint finish.

MODELS: 1403611 ; 1403612; 1403621; 1403622

4309 (Almond)

4310 (Black)

4311 (Red)

4312 (White)

MODELS: 2203611; 2203612; 2203621; 2203622 3003611; 3003612; 3003621; 3003622

4313 (Almond)

4314 (Black)

4315 (Red)

4316 (White)

ALL MODELS:

For additional vent cap protection, Vent Cap Guard 9308 may be used. This mounts to the outside of the exterior wall over the vent cap.

NOTE

Accessories are identified on the carton by their manufac- turing number. (For example: 9301; 9302; 9303.) These manufacturing numbers are also listed on the furnace rating plate so you can be sure you have the accessory that fits your furnace.