FOR YOUR SAFETY, READ BEFORE LIGHTING

FOR YOUR SAFETY, READ BEFORE LIGHTING

WILLIAMS GAS CONTROL VALVE P322053 & P322054

I WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell around the appliance area

for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's Instructions.

C.

D.

If you cannot reach your gas supplier, call the fire department.

Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified serv-

ice technician. Force or attempted repair may result in a fire or explosion.

Do not use this appliance If any part has been under water. Immediately call a qualified service technician to

inspect the appliance and to replace any part of the

control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOPI Read the safety information on front label.

2.Turn off all electric power to the appliance (if applicable).

3.Open control access panel.

4.Turn temperature dial clockwise _ to "LO".

5.Push in gas control knob slightly and turn

clockwise/_ to "OFR"

T£14P£RATURF_

 

 

 

 

DIAL_

.

e!

FGAS

CONTROL

 

I_ _

ot / Hoe

_owN

NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.

6.Wait five (5) minutes to clear out any gas, then smell for gas, Including near the floor. If you then smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

7.Loosen wlngnut and open pilot observation door (if equipped).

8.Find pilot--follow metal tube from gas control. The pilot is mounted on side of burner.

9.Push in gas control

knob slightly and

turn

"n--

counterclockwise

I1_

 

to "PILOT."

 

 

10.Push In control knob all the

way and hold in. Immediately THERMO- PILOT

light the pilot.

COUPLE

BURNER

Continue to hold the control knob In for about one (1) minute after the pilot is lit. Release knob and it will

pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 10.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn

the gas control knob to "OFF" and call your service technician or gas supplier.

11.Close pilot observation door, tighten wlngnut (if equipped).

12.Turn gaa control knob counterclockwise Jll;--'_to "ON".

Sensing bulb is now activated. Set temperature dial to desired temperature (1 - 5).

13.Close control access panel.

14.Turn on all electric power to the appliance (if applicable).

TO TURN OFF GAS TO APPLIANCE

1.Turn off all electric power to the appliance if serv- ice is to be performed (if applicable).

2.Open control access panel.

3.Push in gas control knob slightly and turn

clockwise _ to "OFF." Do not force.

4.Close control access panel.

WARNING: DUE TO HIGH SURFACE TEMPERATURES --KEEP CHILDREN, CLOTHING,

FURNITURE OR ANY COMBUSTIBLE MATERIAL AWAY FROM FURNACE.

IMPORTANT: KEEP BURNER AND CONTROL COMPARTMENT CLEAN, SEE INSTALLATION

AND OPERATING INSTRUCTIONS ACCOMPANYING APPLIANCE.

LIGHTING PILOT

If furnace is equipped with a manual spark igniter follow next steps:

1.Review all operating instructions.

2.When lighting pilot, depress red button located to the lower dght side of burner compartment. (view pilot through observation door, repeat several times If necessary)

3.If pilot fails to light or spark is not present while actuating, follow steps 5 through 10.

--16--

Page 16