Woodstock M1001 manual Circuit Information, Circuit Requirements for

Models: M1001

1 44
Download 44 pages 20.05 Kb
Page 13
Image 13

M1001 6" x 26" Vertical Mill

Circuit Information

A power supply circuit includes all electrical equipment between the breaker box or fuse panel in the building and the machine. The power supply circuit used for this machine must be sized to safely handle the full- load current drawn from the machine for an extended period of time. (If this machine is connected to a circuit protected by fuses, use a time delay fuse marked D.)

Note: The circuit requirements listed in this manual apply to a dedicated circuit—where only one machine will be running at a time. If this machine will be connected to a shared circuit where multiple machines will be running at the same time, consult a qualified electrician to ensure that the circuit is properly sized for safe operation.

Circuit Requirements for 110V

This machine is prewired to operate on a 110V power supply circuit that has a verified ground and meets the following requirements:

Nominal Voltage

110V/120V

Cycle

60 Hz

Phase

Single-Phase

Minimum Circuit Size

20 Amps

Plug/Receptacle

NEMA 5-15

Circuit Requirements for 220V

This machine can be converted to operate on a 220V power supply (refer to Voltage Conversion later in this section). The intended 220V circuit must have a verified ground and meet the following requirements:

Nominal Voltage

220V/240V

Cycle

60 Hz

Phase

Single-Phase

Minimum Circuit Size

15 Amps

Plug/Receptacle

NEMA 6-15

-11-

ELECTRICAL

Page 13
Image 13
Woodstock M1001 manual Circuit Information, Circuit Requirements for, Nominal Voltage 110V/120V Cycle 60 Hz Phase