Maintenance

Replacing the External Fuse

The replacement fuse must be rated at 250 A, 32 Vdc. (MEGA Fuse - 2 11/16" x 3/4" Holes: 2" on center. Max. 32-volt DC)

To replace the external fuse:

1. Locate the Fuse Cover

inside the Storage

Compartment of XPower

Powerpack.

AC Charging Input Socket

Fuse Cover

2. Press the tab on the Fuse Cover toward the AC Charge Socket and gently pull outward.

3.Unscrew the two bolts on the fuse.

4.Replace the fuse. Ensure that the replacement fuse is rated at 250 A, 32 Vdc and is of the same type.

5.Tighten the fuse securely with the two bolts.

6.Replace the fuse cover.

Unscrew these two bolts to remove the fuse.

Figure 4-2Replacing the Fuse

4-6