Troubleshooting

Table 5-1Troubleshooting reference

Problem

Possible Cause

Solution

 

 

 

Run time is

Internal battery is not

Recharge using the AC Charger,

less than

fully charged.

until green Charging Status light is

expected.

 

steady.

 

AC appliance power

Check AC appliance power or

 

consumption is higher

wattage rating (or current draw for

 

than expected.

12 V dc appliances) and compare

 

 

with Table 3-1 on page 3–11 and

 

 

Table 3-2 on page 3–14.

 

 

For additional information on

 

 

battery run times, see the Battery

 

 

App Note under the Support Section

 

 

at www.xantrex.com.

 

 

 

Charging

No AC power at the

Ensure power is available at the AC

Status light is

AC wall outlet.

wall outlet.

OFF when AC

AC Charger is faulty.

Replace the AC Charger.

Charger is

connected

 

 

 

 

 

Green

Battery Charge (%)

Unplug the charging sources and any

Charging

reading on digital

appliances and let the XPower

Status light is

display is only

Powerpack rest for 15 minutes to

flashing

accurate when the

obtain an accurate reading.

(indicating

XPower Powerpack

 

recharging)

has been disconnected

 

and Battery

from all appliances

 

Charge (%)

and all charging

 

does not turn

sources for fifteen

 

on.

minutes.

 

 

 

 

The

The compressor may

Turn off the compressor and let it

compressor

have overheated from

cool down.

runs slowly.

excessive use.

 

 

Battery voltage is too

Check the condition of the internal

 

low.

battery. The battery may need to be

 

 

recharged or replaced.

 

 

 