Freedom HF InvChg Owners Guide.book Page 18 Tuesday, April 29, 2014 12:10 PM

Operating in Shore Power Mode

Turning the Inverter Function On and Off

The Inverter Power button on the display panel turns the Freedom HF’s Inverter function ON and OFF. To operate, press the button and hold for one second.

When shore power is NOT present and Inverter mode is ON:

the AC outlets will supply power to any attached appliances when the Inverter Power button is turned ON and

the AC outlets will not supply power to any attached appliances when the Inverter Power button is turned OFF

Inverter Mode Setting is OFF

When the Freedom HF’s Inverter function is turned off (“”) and the AC source is outside the operating range or is disconnected, the Freedom HF will not switch to invert mode. This means that even if the Inverter Power button is pressed to try and turn inverter function on, there will be no power coming from the battery to the AC output terminals. Therefore, any appliance connected to the AC output terminals will not operate.

ELECTRICAL SHOCK HAZARD

Turning the Inverter mode setting to OFF and/or turning the Inverter Power button off do not disconnect DC battery power from the Freedom HF. You must disconnect both AC and DC power before working on any circuits connected to the Freedom HF.

Failure to follow these instructions can result in death or serious injury.

To prevent unnecessary battery discharge, turn the Inverter Power button off when you are not using the Freedom HF.

18

Energy Saver 25-hour Automatic Shut Offa

During invert mode, a 25-hour countdown is initiated when the AC load drops to less than approximately 80 watts and remains below this level. After 25 hours the inverter automatically shuts off to reduce battery discharge and preserve battery life.

a.The feature is available only for Freedom HF 1500 (PN: 806-1544) and Freedom

HF 1800 T (PN: 806-1840-01).