Freedom HF InvChg Owners Guide.book Page 36 Tuesday, April 29, 2014 12:10 PM

Warning Messages

Table 7 Error Codes Displayed on the Display Panel Screen

Error Code

Condition

Mode

Action

 

 

 

 



Low battery voltage detected

Inverting

• Check battery status and recharge if necessary.

 

depending on setting, see

 

• Check for proper DC cable sizing.

 

“Operating Limits” on page 22.

 

• Check for loose connections and tighten if necessary.

 

 

 

 



AC output overload warning

Inverting

• Reduce the loads connected to the AC outlet of the unit.

 

 

 

 



Over-temperature warning

Inverting

• Reduce the loads connected to the AC outlet of the unit.

 

 

 

• Check that the ventilation grille is not blocked.

 

 

 

• Check for ambient temperature and move the unit to a cooler

 

 

 

location whenever possible.

 

 

 

 



not used

 

 

 

 

 

 



not used

 

 

 

 

 

 



High battery voltage (> 15.5 V)

AC shore power

• Check for external charging sources, such as an over voltage

 

 

 

alternator, and disconnect if necessary.

 

 

 

• Confirm that the external charging source is not the cause. The error

 

 

 

may be caused by the internal battery charger system. Call Xantrex

 

 

 

for support.

 

 

 

 



Over-temperature detected on

AC shore power

• Reduce the loads connected to the AC outlet of the unit.

 

the AC transfer relay

 

• Check that the ventilation grille is not blocked.

 

 

 

• Check for ambient temperature and move the unit to a cooler

 

 

 

location whenever possible.

 

 

 

 

36