Freedom HF InvChg Owners Guide.book Page 37 Tuesday, April 29, 2014 12:10 PM

 

 

 

Warning Messages

 

Table 7 Error Codes Displayed on the Display Panel Screen

 

 

 

 

 

 

 

Error Code

Condition

Mode

Action

 

 

 

 

 

 



Battery is bad or external DC

AC shore power

• Check the battery bank.

 

 

load is connected to the battery.

 

NOTE: The battery voltage did not rise above 5 volts DC after 1

 

 

 

 

minute or 10 volts DC after 15 minutes.

 

 

 

 

• Check that the external DC load current consumption is below the

 

 

 

 

charging current setting.

 

 

 

 

• Disconnect the DC load or increase the charger current setting.

 

 

 

 

 

 

For error code :

the display screen and the alarm will turn off after 30 secondsa

after a five-minute shutdown delayb, the unit will immediately stop inverting

For error codes  to :

the unit will stop inverting

For error codes  and :

the unit will stop charging, but

the error code will still show on the display screen and the alarm will remain on, and

AC power will continue to pass through to the AC outlets

a.Available in all models except Freedom HF 1500 and 1800 T. See page 22. b.Available only for the Freedom HF 1500 and 1800 T models. See page 23.

For error code 

the unit will stop charging and shut down, and

the error code will show on the display screen briefly, and

AC power will not pass through to the AC outlets

To reset error codes  to :

1.Remove the AC input.

2.Turn the unit OFF and then turn ON again using the Inverter Power button on the display panel.

975-0390-01-01

37

Page 51
Image 51
Xantrex Technology 806-1055-02, 806-1840, 806-1544, 806-1054-01 manual For error codes  to 