Freedom HF InvChg Owners Guide.book Page 14 Tuesday, April 29, 2014 12:10 PM

Freedom Inverter/Charger Configuration

To adjust the low battery shutdown setting:

3.

Press the Select button once.

By default the low voltage setting is set to Low (“”).

 

The LED screen will display the present (or most recent) low

Low (“”) sets the low battery shutdown threshold to 10.5 V

 

voltage setting. Example, “” for a low shutdown voltage

 

setting.

for all models except Freedom HF 1500.

 

4.

Continue pressing the Select button to cycle through the two –

Middle (“”) is only available to Freedom HF 1500 and

Freedom HF 1800 T. It sets the low battery shutdown threshold

 

” and “” settings (or through three settingsa) until you

to 12.1 V and 11.8 V respectively.

 

reach the desired setting.

High (“”) sets the low battery shutdown threshold to 11.8 V

5.

Press and hold the Select button for five seconds to make the

for all models except Freedom HF 1800 T which sets the low

 

setting permanent.

battery shutdown threshold to 12.1 V.

 

 

See “Shutdown Settings” on page 3 for a summary.

1.Press and hold the Inverter Power button for five seconds.

2.Press the Inverter Power button three times. The LED screen will flash “” intermittently.

To return all feature settings to factory default settings:

1.Press and hold the Inverter Power button for five seconds.

2.Press the Inverter Power button four times. The LED screen will flash “” intermittently.

3.Press and hold the Select button for five seconds to return all feature settings to their factory default settings.

 

 

 

 

 

a.In addition to two settings “” and “”, the middle setting “” is available

 

 

 

 

 

 

 

only for Freedom HF 1500 and 1800 T models (PNs: 806-1544, 806-1840, 806-1840-

 

 

 

 

 

 

01).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

Freedom HF Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 28
Image 28
Xantrex Technology 806-1054-01, 806-1840, 806-1055-02, 806-1544 manual To adjust the low battery shutdown setting