Xantrex Technology XM 1800, XM 1000 manual Sizing the Chassis Ground Cable

Models: XM 1800 XM 1000

1 81
Download 81 pages 18.09 Kb
Page 26
Image 26

 

 

 

Designing Your Installation

 

 

 

 

 

Table 3-1Recommended DC Input Wire Sizes & Lengths

 

 

 

 

 

 

 

 

 

RVa(Recreational Vehicle)

 

 

 

 

 

 

Cable length:

 

 

 

 

Battery to inverter

 

Maximum Battery

 

(one way)

Minimum Cable Size

Fuse Size

 

 

 

 

 

XM 1000

Less than 5 feet (1.5 m)

No. 2 AWG

150 ADC

 

 

 

 

 

XM 1800

Less than 5 feet (1.5 m)

No. 2/0 AWG

250 ADC

 

 

 

 

 

Note: Never use a cable longer than 5 feet (1.5 m) with the XM 1800. Appropriately sized, 90 °C cable can be bought at a welding supply house or a marine supply store.

a. Based on US National Electrical Code NFPA70, Article 551 and Table B310.3, 90C cables.

Sizing the Chassis Ground Cable

See Table 3-2 for the size of the chassis ground cable that runs from the grounding point to the chassis ground stud on the inverter.

Table 3-2Recommended Chassis Ground Cable size

 

Minimum chassis ground cable size

Application

(Stranded cable is recommended)

 

 

Recreational Vehiclea

No. 8 AWG

Note: There are no restrictions on length for the chassis ground cable.

a.Based on US National Electrical Code NFPA70, Article 551, par. 551-20c.

975-0263-01-01