AC Wiring

CAUTION: Reverse polarity

Improper connections (connecting a line conductor to a neutral conductor, for example) will cause the XM 1800 to malfunction and may permanently damage the inverter. Damage caused by a reverse polarity connection is not covered by your warranty.

11.Insert the Line and Neutral wires into the corresponding terminals.

12.Tighten the wire attachment screws to a torque of 1.3–1.8 lbf-ft (1.76– 2.44 Nm). Leave some wiring slack inside the wiring compartment.

Ensure you have maintained correct polarity and that there are no loose strands of wire.

13.Secure the strain-relief clamp.

14.Attach the wiring compartment cover.

15.Connect the outgoing AC wires to the AC load panel.

975-0263-01-01

3–19

Page 38
Image 38
Xantrex Technology XM 1800, XM 1000 manual AC Wiring