Troubleshooting

Troubleshooting Reference

WARNING: Electrical shock and burn hazard

Do not disassemble the XM 1800. It does not contain any user-serviceable parts. Attempting to service the unit yourself could result in an electrical shock or burn.

Table 5-2

Troubleshooting Reference

 

 

 

 

 

Problem

 

Possible Cause

Solution

 

 

 

Low output voltage

You are using a voltmeter

Use a true RMS reading voltmeter such as

(96 VAC–104 VAC)

that cannot accurately

the Fluke 87.

 

 

read the RMS voltage of a

 

 

 

modified sine wave.

 

 

 

 

No output voltage. The Status

The inverter is off.

Turn the inverter on.

LED and the display are off.

No power to the inverter.

Check the wiring to the inverter and to the

 

 

 

 

 

disconnect/battery selector switch.

 

 

The inverter could have

The inverter has probably been damaged.

 

 

been connected with

Return the unit. Damage caused by

 

 

reverse DC input polarity.

reverse polarity is not covered by the

 

 

 

warranty. Information for returning the

 

 

 

inverter is provided in “Return Material

 

 

 

Authorization Policy” on page WA–3.

 

 

No AC power and DC

Connect or apply AC shore power and

 

 

power.

turn the XM 1800 on.

 

 

15 A supplementary

Reset supplementary circuit breaker and

 

 

circuit breaker has

turn the XM 1800 on.

 

 

tripped.

 

 

 

 

 

5–4

975-0263-01-01

Page 59
Image 59
Xantrex Technology XM 1000, XM 1800 manual Troubleshooting Reference