AC Wiring

When making the AC input and AC output connections, observe the correct color code for the appropriate AC wire, as described in Table 3-4.

Table 3-4Color codes for typical AC wiring

Color

AC Wire

 

 

Black

Line

White

Neutral

Green or bare copper

Ground

 

 

Connecting AC Input

WARNING: Shock, fire, and energy hazards

Make sure wiring is disconnected from all electrical sources before handling. All wiring must be done in accordance with local and national electrical wiring codes. Do not connect the output leads of the inverter to any incoming AC source.

1.Install the required circuit breaker in the AC output panel supplying the unit (See Figure 3-6 on page 3–20).

2.Ensure AC power is disconnected from the wire you intend to connect to the XM 1800.

3.Remove the screws securing the GFCI and pull out the GFCI.

4.Remove the GFCI.

5.Remove the right-hand side AC wiring knockout from the front of the unit (see Figure 3-5 on page 3–16).

6.Install a supplied strain-relief clamp in the AC knockout.

7.Locate the terminal block.

The two input terminals are labelled as follows:

N (neutral)

L (line)