Operating Limits

Operating Limits

Power Output

The XM 1800 can deliver up to 1000 watts (XM 1000) or 1800 watts (XM 1800) continuous power. The wattage rating applies to resistive loads such as incandescent lights.

Input Voltage

The allowable XM 1800 input voltage ranges are shown in the following table:

Operating

 

 

Condition

Voltage Range

Comment

 

 

 

Normal

11–15.0 V

 

 

 

 

Optimum

12.0–13.0 V

 

Performance

 

 

 

 

 

Low Voltage Alarm

11.0 V or less

The low battery alarm beeps once

 

 

every two seconds and the display

 

 

shows fault code E01 alternating with

 

 

the battery voltage.

 

 

 

Low Voltage

Less than

The low battery alarm beeps every

Shutdown

10.5 V

second and the display shows fault

 

 

code E02 alternating with the battery

 

 

voltage. The status LED turns red and

 

 

the inverter shuts down to protect the

 

 

battery from being over-discharged.

 

 

 

High Voltage

15.5 V or more

The over-voltage alarm beeps every

Shutdown

 

second and the display shows fault

 

 

code E03 alternating with the battery

 

 

voltage. The status LED turns red and

 

 

the inverter shuts down to protect

 

 

itself from excessive input voltage.

 

 

Note: Although the XM 1800

 

 

incorporates over-voltage protection,

 

 

it can still be damaged if input

 

 

voltage exceeds 16 V.

 

 

 

975-0263-01-01

4–5