Xerox 721P83071 manual Strings, Dates, Record type codes, Error flags, Log flags

Models: 721P83071

1 114
Download 114 pages 61.96 Kb
Page 85
Image 85
Strings

AUDIT LOG RECORD FORMAT

Notes

This section includes all notes referenced in the preceeding tables.

Strings

All fields of type "character" with a length greater than 1 are NULL (binary zero) terminated strings. This reduces the user portion of the string by one character.

Dates

All dates and times are expressed as the number of elapsed seconds since 01-01-1970, 12:00 AM. The double word value will provide for values up to the year 2216.

Record type codes

1 = Log header record

3 = Page detail record

4 = Waste management detail record

5 = Operations log data record

Error flags

Flag bits are set to the hex values shown to indicate what error(s) occurred

0x0001 = duplicate page

0x0002 = out of sequence

0x0004 = missing sequence number

0x0008 = reconciliation error

Log flags

Flag bits are set to the hex values shown to indicate what detail(s) to report

0x0001 = sequence errors

0x0002 = dupe errors

0x0004 = detail vs. summary

0x0008 = operations logged

0x0010 = waste management

0x8000 = report is incomplete

A-8

XEROX 4635 LPS PRODUCT REFERENCE

Page 85
Image 85