Xerox 721P83071 manual Audit flags, Completion status codes, Primary codes

Models: 721P83071

1 114
Download 114 pages 61.96 Kb
Page 86
Image 86
Audit flags

AUDIT LOG RECORD FORMAT

Audit flags

Flag bits are set to the hex values shown to map the state of the audit logger.

0x0001 = input in process

0x0002 = output in process

0x0004 = pre-completion in process

0x0008 = input complete

0x0010 = output complete

0x0020 = log is complete

0x0040 = log is deleted

0x0080 = log completion is pending

0x0100 = BTEXT RPT signal data received

0x0200 = audit logging initialized for a report

0x0400 = BTEXT PAG signal data received

0x1000 = Btrieve in-process files open

0x2000 = Btrieve report audit file open

0x4000 = master directory up to date

Completion status codes

Completion status codes are bit flags. They are classed as primary and secondary, so multiple flags can be set at any one time resulting in a value that is the sum of several flags.

The audit log report will display a description of the most significant status code when multiple flags are set.

Primary codes

0= normal completion

1= operator issued SPACE PAGES command

2= End-of-report encountered during SPACE PAGES command

4= data on page exceeded page size

8= graphic memory size exceeded

16 = font memory size exceeded

32 = report too big for available memory

64= too much data on a page or duplex set-up error

128= irrecoverable graphics imaging error

256= irrecoverable disk or imaging hardware error

512= account page not printed because of aborted job

1024 = unable to recover to page boundry following a system crash

2048 = successive page recovery used

4096 = secondary report completion code used

8192 = operator issued ABORT O command

16384 = operator issued ABORT JOB # command

24576 = operator issued RESET command

XEROX 4635 LPS PRODUCT REFERENCE

A-9

Page 86
Image 86
Xerox 721P83071 manual Audit flags, Completion status codes, Primary codes