Connecting to System
Xerox FS 3270, User's Guide
Keep the settings printout together with this manual for future reference.
Settings Printout at Power-on (PCL mode only)
A settings printout can also be generated at
NOTE:
The Rotary Switch has to be activated at power on in order to change from FSL to PCL or back.
2.4.2. Timeout
The Xerox FS 3270 enables printer sharing between the system and a PC. For this purpose it is possible to specify a timeout period.
If the printer is receiving input on the parallel port, for example, and there is a break in the transmission of data, the other input ports will not be polled for the period speci fied.
The factory default timeout is 20 seconds. The timeout may be changed to suit your requirements. This is done by sending a new setup to the Xerox FS 3270 input port where you want it to take effect. See Chapter 5.
Specifying Timeout.
When specifying the timeout it is also possible to specify a user string. A user string may be used for changing from one symbol set (e.g. Roman 8) to another (e.g. IBM
NOTE:
Settings on the coax input port are automatically reestablished after another input port has been using the printer.
On the parallel and RS input port, you have to program the required setup yourself.
For more detailed information on the commands required, see Chapter 4, Specifying Timeout.
- 17 -