22
External Control Settings
A.Pr : Post pre-amp volume
A.rE : Post reverb volume
bAS : Tone Control (BASS)
mid : Tone Control (MIDDLE)
trE : Tone Control (TREBLE)
PrE : Tone Control (PRESENCE)
Lmt : Limiter Level
SPd : SPEED/TIME settings for the Cho-
rus/Delay Effects
dPt : DEPTH/FEEDBACK settings for the
Chorus/Delay Effects
LE : LEVEL setting for the Chorus/De-
lay Effects
rE : REVERB setting for the Reverb Ef-
fect
The controller that is set in step 3 of this proce-
dure can control the above parameters (setting
values).
5. Press the [FR 3] button
The minimum parameter value (the controller’s
minimum parameter value) will appear in the dis-
play.
Use the [UP]/[DOWN] buttons to set the value
(0.0-10.0).
6. Press the [FR 4] button
The maximum parameter value (the controller’s
maximum parameter value) will appear in the dis-
play.
Use the [UP]/[DOWN] buttons to set the value
(0.0-10.0).
7. Press the [UTILITY] button to return to the Play
Mode.
A foot controller (expression pedal) (optional), such as the YAMAHA FC-7, connected to the
AG-Stomp’s EXP. PEDAL jack lets you control the volume and tone of the AG-Stomp and
effect parameters (setting values). These same parameters can also be controlled with MIDI
control changes.
* In the following section, the abbreviation [FR 1] button refers to the [FEEDBACK REDUCTION 1] button, etc.

Procedure

1. In the Play Mode, press the [MANUAL] and
[UTILITY] buttons simultaneously.
CtL” will appear in the display when the Exter-
nal Control Setting Mode is entered.
2. Press the [LIMITER] button.
A control number will appear in the display.
Use the [UP]/[DOWN] buttons to set a control
number.
Up to 8 external control settings (control num-
bers: 1-8) can be stored in the AG-Stomp’s
memory. Eight individual controllers can be used
to control individual parameters or a single con-
troller can be used to control 8 parameters.
3. Press the [FR 1] button.
The controller type will appear in the display.
Use the [UP]/[DOWN] buttons to set the type of
controller.
EP : The foot controller connected to the
AG-Stomp’s EXP. PEDAL jack is the
controller.
1-31, 64-95: Control change data re-
ceived from an external MIDI de-
vice connected to the AG-Stomp’s
MIDI IN jack does the controlling.
Select the appropriate control
change number. (Refer to the
Owner’s Manual for the external
MIDI device for information on MIDI
control change numbers.)
4. Press the [FR 2] button
The parameter type will appear in the display.
Use the [UP]/[DOWN] buttons to set the type of
parameter you want controlled.
oFF : off (no control)
bAL : Balance between the DIRECT tone
and the MIC tone (BLEND)
StE : The stereo position of the two mics
(STEREO)
These external control settings are stored
with patch data.
Also, in the Utility Mode, there is a function
that is not related to patch data settings that
sets the Utility Mode’s External Control to
always ON (effective) or always OFF. ( page
26)