Installation

2Parity Check

The parity check is used for error correction during data transmissions. If parity- checking has to be disabled, the shunt on the Parity jumper switch should be removed.

Parity ON (Default)

Normally leave this setting alone.

Parity OFF

1 2 4

ID SELECT

PARITY

TERMINATOR BLOCK SIZE

1 2 4

ID SELECT

PARITY

TERMINATOR BLOCK SIZE

By factory default, the Parity switch is set to “ON” and should normally be left in this state.

3Termination

Terminators prevent SCSI signals from being reflected off the last device in the chain. The SCSI terminator switch should be set to “ON” if the CRW8824S is the last device on the internal SCSI chain. If the CRW8824S is not the last device on the internal SCSI chain, the shunt on the Terminator jumper switch should be removed.

Computer

Hard disk drive

(unterminated)CRW8824S (terminated)

MO drive

(terminated)

SCSI adapter card

Terminator

By factory default, the Terminator switch is set to “ON.”

11