40 Chapter 4Recording
D24—Owner’s Manual
Using Normal & Fine Metering
Track meters function in one of two modes: Normal or Fine. In Normal mode, the
meter range is from –60 dB to 0 dB. In Fine mode, it’s from –26 dB to 0 dB.
Fine mode is useful for accurate level setting when recording reference tones at –10,
–14, –18, or –20 dB, but can also be used for precise metering with normal recording.
The normal and fine meter modes are set using the Level Meter function.
1Press the [UTILITY] button.
The UTILITY indicator lights up.
2Use the JOG/DATA dial to select LEVEL METER, and then press the [ENTER]
button.
The currently selected meter mode appears on the display.
3Use the JOG/DATA dial to select either NORMAL or FINE.
4Press the [ENTER] button to activate your selection, or the [CANCEL] button
to cancel the Level Meter function.
5Press the [UTILITY] button again to leave utility.
The UTILITY indicator goes out.