30 Connections and Setup
01V96i—Owner’s Manual
Signals that are currently assigned to the output
connectors are shown in the parameter boxes (1)
underneath the connector numbers. The parameter
indicators are explained below:
•– ..........................................No assignment
•BUS1–BUS8... ..................Bus Out 1–8 signals
•AUX1–AU X8 ...................Aux Out 1–8 Signals
•ST L/R................................Stereo Out signals
•INS CH1–INS CH32......Input Channels 1–32
Insert Outs
•INS BUS1–INS BUS8....Bus Out 1–8 Insert Outs
•INS AUX1–INS AUX8..Aux Out 1–8 Insert Outs
•INS ST-L/ST-R................Stereo Out Insert Outs
•CAS BUS1–BUS8...........Bus Out 1–8 Cascade
Outs
•CAS AUX1–AUX8..........Aux Out 1–8 Cascade
Outs
•CAS ST-L/ST-R...............Stereo Out Cascade Outs
•CASSOLOL/CASSOLOR..Solo Channel Cascade
Outs
2. Use the cursor buttons to move the cur-
sor to a patch parameter (1) you wish to
change, and rotate the Parameter wheel
or press the [INC]/[DEC] buttons to mod-
ify the patching.
3. Press [ENTER] to confirm the change.
Patching output signals to USB OUTBy default, the following output signals are assigned to
USB OUT.
•USB OUT1–8..... Bus Out 1–8 signals
•USB OUT9–16...Bus Out 1–8 signals
If you wan t to ch ang e or ver if y t his pat ch ing , pr oc eed as
follows.
1. Press [PATCH] repeatedly until the fol-
lowing page appears.
The parameter boxes underneath each number
indicate the currently-assigned signal routing. The
meaning of these indicators are explained below.
•– .........................................No assignment
•BUS1–BUS8.....................Bus Out 1–8 signals
•AUX1– AUX8................... Aux Out 1–8 signals
•ST L/R.............................. .Stereo Out signals
•INS CH1–INS CH32.....Input Channels 1–32
Insert Outs
•INS BUS1–INS BUS8....Bus Out 1–8 Insert Outs
•INS AUX1–INS AUX8..Aux Out 1–8 Insert Outs
•INS ST-L/ST-R................Stereo Out Insert Outs
2. Move the cursor to a parameter box, and
use the Parameter wheel (or
[INC]/[DEC]) to modify the patching.
3. Press [ENTER] to confirm the change.
Tip: To restore the default patching, recall Output Patch