255027-YTG-B-0507

TABLE 10: SUPPLY AIR BLOWER PERFORMANCE (BP048 BELT DRIVE) - SIDE DUCT APPLICATION

AIR

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE - IWG1

 

 

 

 

 

FLOW

 

0.2

 

 

0.3

 

 

0.4

 

 

0.5

 

 

0.6

 

 

0.7

 

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RPM

WATTS

BHP

RPM

WATTS

BHP

RPM

WATTS

BHP

RPM

WATTS

BHP

RPM

WATTS

BHP

RPM

WATTS

BHP

1000

-

-

-

-

-

-

-

-

-

789

527

0.57

831

567

0.61

874

602

0.65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1100

-

-

-

-

-

-

-

-

-

811

559

0.60

854

599

0.64

896

634

0.68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

-

-

-

-

-

-

791

548

0.59

833

592

0.63

876

632

0.68

918

667

0.72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1300

-

-

-

772

539

0.58

813

584

0.63

855

628

0.67

898

668

0.72

940

703

0.75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1400

-

-

-

795

579

0.62

836

624

0.67

878

668

0.72

920

708

0.76

963

744

0.80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

779

578

0.62

819

624

0.67

860

669

0.72

902

713

0.77

944

753

0.81

987

789

0.85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1600

804

629

0.67

844

675

0.72

885

720

0.77

927

764

0.82

970

804

0.86

1013

839

0.90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1700

831

685

0.74

871

731

0.78

913

777

0.83

955

820

0.88

997

861

0.92

1040

896

0.96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

860

748

0.80

901

794

0.85

942

839

0.90

984

883

0.95

1026

923

0.99

1069

958

1.03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1900

891

817

0.88

931

862

0.92

973

908

0.97

1015

951

1.02

1057

992

1.06

1100

1027

1.10

2000

924

891

0.96

964

937

1.01

1005

982

1.05

1047

1026

1.10

1090

1066

1.14

1133

1102

1.18

2100

959

972

1.04

999

1018

1.09

1040

1063

1.14

1082

1107

1.19

1125

1147

1.23

1167

1182

1.27

2200

996

1059

1.14

1036

1104

1.18

1077

1150

1.23

1119

1194

1.28

1162

1234

1.32

-

-

-

2300

1034

1151

1.24

1075

1197

1.28

1116

1243

1.33

1158

1286

1.38

-

-

-

-

-

-

2400

1075

1250

1.34

1115

1296

1.39

1156

1341

1.44

-

-

-

-

-

-

-

-

-

2500

1118

1354

1.45

1158

1400

1.50

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE - IWG1

 

 

 

 

 

FLOW

 

0.8

 

 

0.9

 

 

1.0

 

 

1.1

 

 

1.2

 

 

1.3

 

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RPM

WATTS

BHP

RPM

WATTS

BHP

RPM

WATTS

BHP

RPM

WATTS

BHP

RPM

WATTS

BHP

RPM

WATTS

BHP

1000

917

631

0.68

959

651

0.70

1001

660

0.71

1041

658

0.71

1081

642

0.69

1119

611

0.66

1100

939

663

0.71

981

683

0.73

1023

692

0.74

1064

690

0.74

1103

674

0.72

1141

643

0.69

1200

961

696

0.75

1003

716

0.77

1045

725

0.78

1086

723

0.78

1125

707

0.76

1163

676

0.73

1300

983

732

0.79

1025

752

0.81

1067

761

0.82

1108

759

0.81

1147

743

0.80

1185

712

0.76

1400

1006

772

0.83

1048

792

0.85

1090

801

0.86

1130

799

0.86

1170

783

0.84

-

-

-

1500

1030

817

0.88

1072

837

0.90

1114

847

0.91

1154

844

0.91

1194

829

0.89

-

-

-

1600

1055

868

0.93

1098

888

0.95

1139

897

0.96

1180

895

0.96

-

-

-

-

-

-

1700

1083

924

0.99

1125

944

1.01

1166

954

1.02

-

-

-

-

-

-

-

-

-

1800

1112

987

1.06

1154

1007

1.08

-

-

-

-

-

-

-

-

-

-

-

-

1900

1142

1055

1.13

1185

1075

1.15

-

-

-

-

-

-

-

-

-

-

-

-

2000

1175

1130

1.21

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2100

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2200

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2300

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2400

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2500

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK61 blower sheave and A36 belt.

AK56 blower sheave and A36 belt - Field installation required.

Unitary Products Group

17

Page 17
Image 17
York BP 036 warranty 1000 789 527 831 567 874 602