Yukon Advanced Optics Oil Furnace owner manual Specifications, MODEL LWO-112Oil, Input rating

Models: Oil Furnace

1 64
Download 64 pages 37.66 Kb
Page 10
Image 10
Specifications

Specifications

 

MODEL LWO-112 (Oil)

Input rating

......................................................................................................................................140,000 BTU/HR

Nozzle

1.0 G.P.H. - 80 H

Burner

Wayne Model - MSR

Input rating

MODEL LWG-112 (Gas)

140,000 BTU/HR

 

Output rating

112,000 BTU/HR

 

NAT

LP

Orifice

7/32" (.218 dia.)

9 (.136 dia.)

Manifold Pressure

3.5 W.C.P

11.0 W.C.P.

Burner

Wayne Model P250-AF-DI-Y

Blower Size (Belt Drive)

MODEL LWO-112 or LWG-112

10" x 10"

 

Blower C.F.M

800 - 1800

Motor Size

1/3 - 1/2 - 3/4 HP

Firebrick Lined

(7) 9” x 6” x 2” • (8) 12” x 6” x 2”

Cast Iron Grates - Standard

(3) 16” x 8”

Wood Fire Door

11" x 10"

Air Filter

20" x 25" x 1"

Wood Combustion Chamber Size

24" x 16"

 

MODEL LWO-168 (Oil)

Input rating

189,000 BTU/HR

Output rating

151,000 BTU/HR

Nozzle

1.35 G.P.H - 80 H

Burner

Wayne Model - MSR

Input rating

MODEL LWO-168 (Gas)

189,000 BTU/HR

 

Output rating

151,000 BTU/HR

 

NAT

LP

Orifice

“F" (.257 dia.)

“23” (.154 dia.)

Manifold Pressure

3.5 W.C.P

11.0 W.C.P.

Burner

Wayne Model P250-AF-DI-Y

Blower Size (Belt Drive)

MODELS LWO-168, or LWG-168

11" x 10"

 

Blower C.F.M

1200 - 2000

Motor Size

1/3 - 1/2 - 3/4 HP

Firebrick

(10) 9” x 6” x 2” • (7) 12” x 6” x 2” • (1) 9” x 4-1/2” x 2”

Cast Iron Grates - Standard

(3) 18” x 8”

Wood Fire Door

13-1/4" x 13-1/4"

Air Filter

20" x 25" x 1"

Wood Combustion Chamber Size

24" x 18"

NOTE: It is recommended that a 2", non combustible, raised pad be used for the furnace. This will prevent moisture from getting under the furnace and causing corrosion.

Questions? Visit www.yukon-eagle.com or call 1-800-358-0060

10

Page 10
Image 10
Yukon Advanced Optics Oil Furnace Specifications, MODEL LWO-112Oil, Input rating, 1.0 G.P.H. - 80 H, Wayne Model - MSR