Yukon Advanced Optics Oil Furnace Installation, Damper Control, Draft Tube Assembly, Fig

Models: Oil Furnace

1 64
Download 64 pages 37.66 Kb
Page 16
Image 16
DAMPER CONTROL

Installation

DRAW COLLAR (Models LWO-168 & LWG-168 ONLY) Firmly attach the draw collar around the stainless steel smoke pipe. Keep the field installed smoke pipe at least 2 " away from draw collar. This will insure that smoke leaving the furnace will not be drawn into the circulating air stream. See Fig. 11.

NOTE: Only Models LWO-168 and LWG-168 are equipped with a draw collar.

NOTE: If barometric damper control is installed horizontally as illustrated, it must be at least 8 inches from furnace smoke outlet.

CHIMNEY

DAMPER CONTROL

NOTE: Refer to the wiring diagrams in the back of manual in “Exploded Views and Parts List.”

Remove control from accessory box and install as follows:

1.Remove the four screws that hold the gasket to the DS-103 panel.

2.Mount the DS-103 to the draft tube using screws removed above. Make sure gasket stays in place. See Fig. 12

3.Loosen the two screws located at slotted end of draft tube, and remove remaining 10 screws. Make sure gasket stays in place.

4.Mount DS-103 control and draft tube assembly to furnace as shown. See Fig. 12

5.The electrical connections will be completed later in the Installation Instructions.

Draft Tube

Assembly

SMOKE

PIPE

 

DRAW

 

 

COLLAR FILTER

 

DRAFT

DOOR

 

 

 

REGULATOR

FIG. 11

FIG. 12
Damper Control

Questions? Visit www.yukon-eagle.com or call 1-800-358-0060

16

Page 16
Image 16
Yukon Advanced Optics Oil Furnace owner manual Installation, Damper Control, Draft Tube Assembly, Fig