| 24 Volt Field Wiring |
| ||
| OIL OR GAS AND WOOD HEATING ONLY | ||||
|
| Honeywell FocusPro 6000 | Honeywell FocusPro 5000 |
| |
|
| Thermostat |
| Thermostat |
|
|
| RC R Y C W G | RC R Y C W G |
| |
24 volt |
|
|
|
|
|
Transformer |
|
|
|
|
|
R |
|
|
|
|
|
C |
|
|
| C | Terminal 1 |
|
|
|
|
| |
|
|
|
| R | controls wood |
|
|
|
| damper/wood | |
|
|
|
|
| |
|
|
|
| 1 | thermostat |
|
|
|
|
| |
|
|
|
| 2 |
|
|
|
|
|
| Terminal 2 |
|
| OIL or GAS T |
| T | controls |
|
|
| gas/oil burner | ||
|
| BURNER T |
| T | thermostat |
|
|
|
| ||
OIL OR GAS AND WOOD HEATING WITH AIR CONDITIONING | |||||
|
| Honeywell FocusPro 6000 | Honeywell FocusPro 5000 | ||
|
| Thermostat |
| Thermostat |
|
| Fan | RC R Y C W | G | RC R Y C W | G |
24 volt | Relay |
|
|
|
|
|
|
|
|
| |
Transformer |
|
|
|
|
|
|
|
|
|
| Terminal 1 |
|
|
|
|
| controls wood |
| R |
|
|
| damper/wood |
|
|
|
| thermostat | |
| C |
|
|
| C |
|
|
|
|
| R |
|
|
|
|
| 1 |
|
|
|
|
| 2 |
AC |
| OIL or GAS T |
| T | |
Condensing |
| BURNER T |
| T | |
Unit |
|
| |||
Compressor |
|
|
| ||
| Relay |
|
|
| Terminal 2 |
|
|
|
|
| controls |
|
| 24 |
|
| gas/oil burner |
|
|
|
| thermostat |