Installation

Installation

PLACE FURNACE

Review all instructions in the Planning Your Installation section. Place the furnace in the pre- selected location.

Refer to Figs. 4 & 5 (on page 12) in the Planning Your Installation section. Make sure the furnace is level.

SECONDARY AIR INTAKE COVER

1.Remove secondary air intake cover from accessory package and align over mounting holes located above fire door assembly on face of furnace. See Fig. 7.

2.Insert 12 ea. # 10 x 3/4 hex HD drill screws (furnished with cover) through mounting holes and tighten.

SMOKE

SECONDARY AIR SHUT OFFPIPE MODELS LWO-112 & LWG-112 ONLY

1.Remove round secondary air shut off disc from plastic bag.

2.Screw disc to the intake cover just installed.

Opening the disc when burning wood provides room air to the round perforated tubes between the top and bottom row of firebrick, thereby causing secondary combustion of the unburned wood gases as they leave the initial flame. This patented feature increases wood burning efficiency up to 40% while reducing smoke and creosote. When burning gas or oil for extended periods of time, this disc should be closed.

It is not necessary to provide this disc on models LWG- 168 and LWO-168. Maximum efficiency is achieved without this disc.

DRAFT TUBE INSTALLATION

Remove the 8 bolts already screwed in where draft tube gasket is in place. Mount tube over gasket. Make sure the gasket aligns with the long slotted hole. Bolt tube to the furnace below the fire door. See Fig. 7 & 8.

RETURN AIR

WARM AIR

PLENUM

PLENUM

FUME SWITCH

(GAS MODEL ONLY)

DS-103 DAMPER

CONTROL

24-VOLT

TRANSFORMER

FIG. 6

FIG. 7

Secondary Air

Shut Off Disc

DRAFT TUBE

FIG. 8