SMOKE BAFFLES

Installation

SMOKE BAFFLES

The smoke baffles are factory installed. They must be checked to see that they have not become dislodged during shipping. See Fig. 14-A. Complete the following steps to check the baffles:

1.Hold the baffle in proper position. Tilt the rear up to clear baffle mounting brackets.

2.Push baffle up to top of combustion chamber above all three brackets, level off, slide left and lower onto mounting brackets.

3.Check to see that all three brackets are engaged.

4.Repeat with second baffle, making sure baffles interlock as shown. See Fig 14-B. When properly installed, baffles will not move more than 1/4" in any direction.

NOTE: Failure to have baffles properly installed

will severely reduce combustion efficiency.

FIG. 14-A

FIG. 14-B

Questions? Visit www.yukon-eagle.com or call 1-800-358-0060