Zenith HCS5610 warranty Monitor Ventilation

Models: HCS5610

1 72
Download 72 pages 57.56 Kb
Page 8
Image 8

Ventilation

The HCS5610 Integrator Box as well as Plasma monitors generate heat during operation and need to be provided with adequate ventilation to assure continued reliable operation. See recommenda- tions below.

Ventilation Clearance

Proper clearance for air to flow around the HCS5610

Integrator Box must be provided.

Monitor Ventilation

Be sure proper ventilation is provided for the monitor, see monitor installation guide for specified ventilation requirements.

1

There are ventilation holes on four sides of the the

HCS5610 box provided for ventilation cooling.

 

 

a. If the box is mounted vertically, the vents on the

 

sides should be located on the top and bottom for

 

free vertical air movement.

 

b. If the box is mounted horizontally, the vents should

 

be located at the sides and top of the enclosure

 

(never mount the box with vents facing down). See

 

drawings to the right for reference.

2

The vent holes should never be blocked or obstructed to

airflow but have an unimpeded path through any enclo-

 

 

sure back to room temperature air.

3

The unit and its venting, should not be installed near

heat sources such as radiators or heating ducts.

 

4

If the unit is placed in an enclosure, tests should be run

to confirm that the ambient temperature around the unit

 

 

under normal expected operating conditions is stable and

 

does not exceed 40 degrees Celsius (104F). This can be

 

determined by placing a thermometer near the air intake

 

vents in the proposed enclosure and measuring the

 

temperature every hour, under normal operating

 

conditions, until two successive readings repeat.

 

If temperature does not stabilize but keeps increasing

 

above 104F, ventilation is inadequate and needs to be

 

improved.

5

Always provide adequate air space between the ventila-

tion areas and adjacent structures.

 

 

*Note:

 

In addition to the ventilation requirements shown, be sure to

 

allow enough clearance (4” - 5”) for wiring clusters attached to

 

the Integrator Box.

Vent Holes

Vent Holes

Vent Holes

Vent Holes

Vent Holes

Vent Holes

P A G E 8

Page 8
Image 8
Zenith HCS5610 warranty Monitor Ventilation