Zenoah EXZ2610DL owner manual Spark Plug, REPLACEMENT PLUG IS A NGK CMR7H, Muffler, Spark Arrester

Models: EXZ2610DL

1 32
Download 32 pages 35.57 Kb
Page 26
Image 26
SPARK PLUG

EXZ2610DL

9. Maintenance

SPARK PLUG

Starting failure and misfiring are often caused by a fouled spark plug. Clean the spark plug and check that the plug gap is in the correct range. For a re- placement plug, use the correct type specified by

ZENOAH.

0.6~ 0.9mm

REPLACEMENT PLUG IS A NGK CMR7H.

•REPLACEMENT PLUG IS A NGK CMR7H.MUFFLER IMPORTANT

Note that using any spark plug other than those des- ignated may result in the engine failing to operate prop- erly or in the engine becoming overheated and dam- aged.

To install the spark plug, first turn the plug until it is finger tight, then tighten it a quarter turn more with a socket wrench.

9.8~ 11.8 N.m. TIGHTENING TORQUE: (1 ~ 1.2 kg.m.)

MUFFLER

•Note that failing to do so may result in the engine catching on fire.SPARK ARRESTER WARNING

Inspect periodically, the muffler for loose fasten- ers, any damage or corrosion. If any sign of ex- haust leakage is found, stop using the machine and have it repaired immediately.

Note that failing to do so may result in the engine catching on fire.

SPARK ARRESTER

The muffler is equipped with a spark arrester to pre- vent red hot carbon from flying out of the exhaust out- let. Periodically inspect and clean as necessary with a wire brush. In the State of California it is required by law (Section 4442 of the California Public Resources Code) to equip a spark arrester when a gas powered tool is used in any forest covered, brush covered, or grass covered unimproved land.

(1)

(1) Spark arrester

INTAKE AIR COOLING VENT

INTAKE AIR COOLING VENTManual background WARNING

Never touch the cylinder, muffler, or spark plugs with your bare hands immediately after stopping the engine. The engine can become very hot when in operation, and doing so could result in severe burns.

When checking the machine to make sure that it is okay before using it, check the area around the muffler and remove any wood chips or leaves which have attached themselves to the brushcutter. Failing to do so could cause the muf- fler to become overheated and that in turn could cause the engine to catch on fire. Always make sure that the muffler is clean and free of wood chips, leaves, and other waste before use.

Check the intake air cooling vent and the area around the cylinder cooling fins after every 25 hours of use for blockage, and remove any waste which has attached itself to the brushcutter. Note that it is necessary to remove the engine cover shown in (MA5) in order to be able to view the up- per part of the cylinder.

GB-26

Page 26
Image 26
Zenoah EXZ2610DL owner manual Spark Plug, REPLACEMENT PLUG IS A NGK CMR7H, Muffler, Spark Arrester, Intake Air Cooling Vent