Zhone Technologies, Inc.

IMACS Product Book, Version 4

 

 

 

 

 

 

 

 

 

 

Model 8905 Power Supply, 120/240 VAC

 

 

 

Input Voltage

90 Vrms to 260 Vrms

 

 

Input Frequency

50/60 Hz

 

 

Output Power

100W max

 

 

Output Voltage

-48.0 VDC

 

 

Output Current

2 amp

 

 

Maximum Number per system

2

 

 

Redundancy

Optional

 

 

Ventilation

Convection cooled

 

 

Approvals

UL 1459, UL 1950, CSA-C22.2 No.950, CE Mark

 

 

Model 8908 Power Supply, 105/240 VAC

 

 

 

Input Voltage

90 Vrms to 260 Vrms

 

 

Input Frequency

50/60 Hz

 

 

Output Power

300 W max

 

 

Output Voltage

-48.0 VDC

 

 

Output Current

6.25 amp

 

 

Maximum Number per system

2

 

 

Redundancy

Optional

 

 

Ventilation

Forced Air, (120mm Fan)

 

 

Approvals

UL 1459, UL 1950, CSA-C22.2 No.950

 

Ring Generator

Ring generators are required to supply ringing current whenever there are Foreign Exchange Station (FXS) Cards operating in the unit or if there is one or more Foreign Exchange Office (FXO) ports that are used in Manual Ring Down (MRD) mode.

The current ring generator model is: Model 890620

Model 890620,the internal ring generators, will support up to 24 simultaneously ringing phones. Additional ringers can be added depending on the chassis and application, (see table 5). The exact number of simultaneously ringing subscriber lines supported is a function of the Bell Ringer Equivalency Number (REN) of the attached devices and the loop impedance. The user may attach an external ring generator to the IMACS terminal block location marked RGR.

The model 890620 is an enhanced version of the current 8906 ring generator. This model has improved operating efficiency and inrush current limiting.

Table —Ring Generator Specifications

 

 

Model 890620 Ringing Generator

 

 

 

 

 

Input Voltage

 

42 to 57 VDC, linear = 0.84 max.

 

 

Efficiency

 

57% at 48 V and 1 kOhm load

 

 

Protection

 

5 A slow blow fuse, primary current limiting

 

 

Noise

 

Less than 32dBrnc

 

 

Output Voltage

 

100 VDC rms default – adjustable from 60 to 105 Vrms

 

 

Output Current

 

160 mA RMS continuous, 230 mA RMS cadence

 

 

Output Frequency

 

20 Hz +/- 1 Hz

 

 

Operational Modes

 

Strap selectable: Master or Slave

 

 

Maximum Number per system

IMACS 600

1

 

 

 

 

IMACS 800

1 Master, 3 slaves (DC operation)

 

 

 

IMACS 900

2 slaves (AC operation)

 

 

 

1 Master, 1 slave

 

 

Redundancy

 

There is no provision for Master Ringer redundancy, however

 

 

 

 

the slave units provide fail-over protection

 

 

 

 

 

 

 

March 2001

 

Page 20

 

Page 24
Image 24