IMACS Diagnostic Capabilities

Status and Alarm Management

The IMACS supports a comprehensive alarm message generation and reporting capability that provides the system operator with a complete view of the operation of the system. Alarm messages that are supported include, Out-Of- Service (OOS) condition (any card, module, power supply or ringing generator that fails or is removed from the system), No Signal (NOS), Loss of Synchronization (LOS), AIS alarm, CGA-Red alarm, CGA-Yellow alarm, Excessive Error Rate (EER), Alarm card sensor (SENSOR), D-channel out of service (DCHAN), Switch to redundant card (SWITCH), User card/port alarm (UCA), System reset (RESET), Alarm Cut-Off (ACO), Clock Sync alarm (SYNC), Error rate above 10e-3 (EER-3), DS3 PCLP Out of Framing (PLC_OOF), DS3 PCLP Loss of Frame (PLC_LOF) and DS3 PCLP Yellow alarm (PLC_YEL).

The IMACS supports the setting of filters for each alarm message that is generated by the system. These three filters define the manner in which the alarm will be reported and take precedence over the designation of the level of the alarm.

Setting the filter of a specific alarm to “report” will cause the system to display the alarm message on the screen, log it into the alarm history file and report it to a remote device by dialing a pre-programmed telephone number through the built-in modem or by sending an SNMP trap via IP.

Setting the filter to “log” will (a) display the alarm message on the screen and (b) log it into the alarm history file.

Setting the filter to “ignore” will cause the alarm indication to be ignored by the system.

In addition to the three filters, each alarm may be designated as “info”, “major”, “minor” or “critical”. When used in conjunction with the Model 840X External Alarm card, the occurrence of any alarm designated as “major” will trigger a form-C contact on the External Alarm card, which in turn can serve to activate an external device such as a bell or light. Similarly, the occurrence of any alarm designated as “minor” would trigger a different contact and, therefore, activate a different external indicator.

The system supports a standard feature known as Alarm Cut-Off (ACO). If the ACO function is enabled, by setting it to “log” or “report”, then any major alarm that is set to “report” or “log” will automatically cause an ACO message to be generated. The ACO will not disappear until it is manually cleared by the operator.

This feature is useful in situations where an alarm condition occurs and then clears itself while the system is unattended. When the operator returns, there will be no indication on the console screen that anything had happened. However, if the ACO function is enabled, then the ACO message will remain on the screen thereby notifying the operator that certain events occurred while the node was unattended. The operator can then query the alarm history file for further information.

Alarms may be set to “report” in which case the IMACS will dial a remote device after a “wait” period. The user may define the wait period for both Major and Minor alarms. The wait period can be between 1 and 500 seconds for a Major alarm and between 1 and 32,000 seconds for a Minor alarm.

The user may specify in software the remote device’s telephone number, printout retry interval if the remote device is busy (1 minute to 60 minutes, in 1 minute intervals) and the maximum number of times (from 1 to 99) that the system will attempt to contact the remote device before giving up.

The user may customize the appearance of alarm messages by specifying the order that the six message elements should appear in. Those elements are: (1) slot position (“address”), (2) card type (“model”), (3) alarm type (“alarm”), and (4) start and stop time and date stamps (“time”), (5) alarm sequence number “number”, (6) alarm severity (“severity”).

Integral Test Capabilities

The IMACS provides a comprehensive set of built-in diagnostic tools that enable the operator to remotely troubleshoot and resolve problems. In addition to the system-generated alarm messages described above, the