Zhone Technologies, Inc. | IMACS Product Book, Version 4 | ||
|
|
|
|
|
|
| |
|
| (toward user) and Tandem (toward CO) | |
| E&M Sensor Characteristics | ||
|
| Sensitivity > 2.5 mA | |
| Nominal Transmit TLP | Software configurable, | |
|
| 17.5 dB +14.5dB, steps of 0.1 dB | |
| Nominal Receive TLP | Software configurable, | |
|
| 16.3dB +7.5dB steps of 0.1dB | |
| Termination Impedance | 600 Ohms with 2.16 uF capacitor in series | |
|
|
|
|
| Delay Specification |
|
|
| Absolute Group Delay | <600 us | |
| (dependent on codec) |
|
|
| Peak to Average Ratio (PAR) | 94 to 97 | |
| Standards Conformance |
|
|
| AT&T TR43801 | Digital Channel Bank Requirements and Objectives – November 1982 | |
| Bell | Functional Criteria for Digital Loop Carrier System – January 1993 | |
| BellCore | Network | |
|
| Protection | |
| (11/96) – Transmission Performance Characteristics of Pulse Code | ||
| Modulation (replaces G.712, G.713, G.714 and G.715) | ||
| Transmission Characteristics of 2 | ||
| Exchange | ||
|
| Transmission Characteristics of 4 | |
|
| Exchange | |
| FCC Part 68 | Requirements for Connection of Terminal Equipment Systems and | |
|
| Protective Apparatus to the Telephone Network | |
| FCC Part 15 | Subpart B | |
| UL 1459 | Standard for Safety, Telephone Equipment | |
| UL 1950 | UL Standard for Safety of Information Technology Equipment | |
| CE EN 500 | Electromagnetic compatibility generic emission standard Part 1 | |
|
| Residential, commercial and light industry | |
| CE EN 500 | Electromagnetic compatibility generic immunity standard Part 1 | |
|
| Residential, commercial and light industry | |
| CE EN 60 950/A2 | Safety of information technology equipment including electrical | |
|
| business equipment |
March 2001 | Page 36 |