Zhone Technologies, Inc.

IMACS Product Book, Version 4

The 802060 Dual T1 HDSL WAN Card has two ports that that are equipped with 82100 T1 HDSL modules. The HDSL modules provide 1.544 Mbps T1 transmission over 2 copper pairs. Both modules have to be installed for proper operation and do not support redundancy. Table 9 depicts the various T1/E1 WAN card specifications. In addition to the specifications listed in Table 9 (below) the 802060 card is in conformance with ITU-T Q.421 and ITU-T Q.422. The transmission range is software selectable for the following: 0, 133, 266, 399, 533 or 655 ft. (up to 200 meters), and CSU (allowing connections to the equipment side of a co-located external CSU over a short distance, four-wire cable). Software selectable line build out (LBO) settings are also available for all of the aforementioned transmission ranges.

Table 9—WAN Card Hardware Specifications

Model

 

Number of Ports

Number of

Physical Interface

Electrical Interface

 

 

 

 

Cards

 

 

 

800060

 

1

1 to 4

Through 892xxx I/F

811 (T1-DSX/E1-CEPT)

 

 

 

 

 

 

card

812 (T1-CSU) - 1 per port

801060,

 

2

1 to 4

Through 892xxx I/F

811 (T1-DSX/E1-CEPT)

801460

 

 

 

 

card

812 (T1-CSU) - 1 per port

801560

 

2

1 to 4

Through 892xxx I/F

811 (T1-DSX/E1-CEPT)

 

 

 

 

 

 

card

812 (T1-CSU) - 1 per port

802060

 

2

1 to 4

Through 892xxx I/F

82100 is used to provide 1 T1

 

 

 

 

 

 

card

HDSL interface

801160

 

2

1 to 4

Through 892xxx I/F

82030 provides 2*1168Kbps E1

 

 

 

 

 

 

card

HDSL module. Required for each

 

 

 

 

 

 

 

port.

 

T1 Signal Format

 

 

 

 

 

 

Electrical Interface

 

ANSI T1.102/T1.403, DSX-1, balanced 100 Ω

 

Frame Format

 

D4, ESF, Subscriber Loop Carrier (SLC) 96, SLCD4

 

Line Coding

 

 

AMI or B8ZS

 

 

 

 

Signaling

 

 

AT&T 43801, 62411, ITU-T, Q.421, Q.422 using Robbed-bit method

 

Error Detection

 

CRC-6, Controlled Slip, Bipolar Violation, Out of Frame

 

Alarm Indication

 

BellCore TR-TSY-000191

 

 

 

SLIP Limit

 

 

126 bits or 138 bits

 

 

 

Bit Rate and Tolerance

 

1.544Kbps +32PPM. Jitter complies with ANSI T1.403

 

E1 Signal Format

 

 

 

 

 

 

Electrical Interface

 

G.703 balanced 120 Ω or unbalanced 75 Ω

 

Coding

 

 

HDB3

 

 

 

 

Framing

 

 

ITU-T G.704 Timeslots consist of 8 bits. Frame consists of 32 time slots,

 

 

 

 

 

Multi-frame consists of 16 frames

 

 

 

Signaling

 

 

CAS, CCS In Timeslot 16 if required.

 

 

 

 

 

 

 

CAS Signaling protocols: AT&T 43801, 62411, ITU-T Q.421 (2)

 

Error Detection

 

CRC-4, Controlled Slip, Out of Frame

 

 

 

Alarm Indication

 

ITU-T G.732

 

 

 

 

Performance and Test Options

 

 

 

 

 

 

Loop backs

 

 

Line, local, channel, loop back generation and detection

 

T1

 

 

FDL in accordance with AT&T 54016 or ANSI T1.403 (8015 only)

 

E1

 

 

National Bit Supporting (G.704)

 

 

 

Standards Conformance

 

 

 

 

 

 

AT&T TR43801

 

Digital Channel Bank Requirements & Objectives

 

AT&T TR54016

 

Requirements for Interfacing Digital Terminal Equipment to Service

 

 

 

 

 

Employing the Extended Superframe Format

 

AT&T TR62411

 

Accunet T1.5 Service, Description and Interface Specifications

 

AT&T TR41449

 

ISDN Primary Rate Interface Specification

 

BellCore TR-TSY-000008

 

Digital Interface Between the SLC 96 Digital Loop

 

BellCore TR-TSY-000191

 

Alarm Indication Signal, Requirements and Objectives

 

 

 

 

 

 

 

 

 

 

March 2001

 

 

 

 

Page 30

 

Page 34
Image 34
Zhone Technologies Network Device manual T1 Signal Format, E1 Signal Format, HDB3, Performance and Test Options