Chapter 12 - Status Registers & Result Codes
12-6Command bit dec hex Function and description Ref.
6 64 30 Enable password protection to profile saving.
When ‘AT&W0’ is issued, and profile 0 in the
NVRAM has this bit set, the supervisory
password will be requested. This bit in profile
0 also protects the supervisory password from
a hardware reset.
*W0
7 128 80 Enable extended numerical result codes from
50-71 when an error corrected connection is
made. Use with ATV0. (see result code table)
V0
S23.6
S36= bit dec hex Bit-mapped register +000
0 0 0 Deny remote request for configuration
(Default) *F0
1 1 Grant remote request for configuration *F1
1 0 0 Write from local profile to remote profile
(Default) *Wab
2 2 Read from remote profile to local profile *Rab
7-5 Security function control
0 0 Disable security function (Default) *G0
32 20 Enable type 1 security with password check.
(ZyXEL to ZyXEL only) *G1
64 40 Enable type 1 security with password check
and call-back (ZyXEL to ZyXEL only) *G2
96 60 Enable type 2 security with password check *G3
128 80 Enable type 2 security with password check
and call-back *G4
160 A0 Enable type 2 security with password check
and call-back, remote site enters the call-back
number
*G5
S37= bit dec hex Bit-mapped register for remote configuration
using panel menu control +000
3-0 0-5 0-5 Remote profile number *Wab
7-4 0-80 0-50 Local profile number *Rab
S38= bit dec hex Bit mapped register +000
0 1 1 Repeatedly dialing default number *Dn S29
3 8 8 DCD ON/OFF sequence follows UNIX
standard, DCD high before connect message
is sent, DCD off after last DCE response is
sent
&C1
S21.4
4 16 10 Auto-mode fax receiving disabled &N0
5 32 20 Disable MNP5 &Kn
S39= bit dec hex Bit mapped register +000
2 4 4 Answer in originating mode ATA
3 8 8 Class 2 Fax Bitfax compatibility:
+FCON at 2400 next phase at 19200
4 16 10 Class 2 Fax mode DTE shifting:
+FCON at current DTE, shift to 19,200 when
entering into the next phase
S40= bit dec hex Bit mapped register +000