FUNCTIONALDESCRIPTION
GROUNDING
|
| 5 |
|
| 4 |
1 | 2 | 3 |
| ||
| 13 | |
|
|
612
11
|
| 9 |
|
|
|
1. | Cord | 10 |
| 8 | 7 |
|
| ||||
2. | Rear handle |
| 8. | Saw chain |
|
3. | Switch |
| 9. | Sprocket cover |
|
4. | Front handle |
| 10. | Sprocket cover nut and washers | |
5. | Hand guard / brake lever | 11. | Drive sprocket |
| |
6. | Guide bar |
| 12. | Oil tank cap |
|
7. | Nose of guide bar | 13. | Chain tension adjusting screw |
WARNING!
Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the cord or plug is dam- aged. If damaged, have it repaired
by a MILWAUKEE service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.
Grounded Tools:
Tools with Three Prong Plugs
Tools marked “Grounding Required” have a three wire cord and three prong ground- ing plug. The plug must be connected to a properly grounded outlet (See Figure A). If the tool should electrically malfunction or break down, grounding provides a low re- sistance path to carry electricity away from the user, reducing the risk of electric shock.
The grounding prong in the plug is con- nected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool's ground- ing system and must never be attached to an electrically “live” terminal.
Your tool must be plugged into an appro- priate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in Figure A.
Double Insulated Tools: Tools with Two Prong Plugs
Tools marked “Double Insulated” do not re- quire grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Labo- ratories, Inc., the Canadian Standard As- sociation and the National Electrical Code. Double Insulated tools may be used in ei- ther of the 120 volt outlets shown in Figures B and C.
|
|
|
|
|
| Symbology |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Double Insulated |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| FPM |
| Feet per minute |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Underwriters |
|
|
|
| ||
|
|
|
|
|
| Laboratories, Inc. |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Volts Alternating Current |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Amperes |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Specifications |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
Cat. | Volts |
|
|
|
|
| Guide | Oil Tank |
| Chain |
| |
No. | AC | Amps | Chain Speed | Bar Size | Capacity |
| Type |
| ||||
|
|
|
|
|
|
|
|
|
| |||
6215 | 120 | 13 | 1800 ft./min. |
| 16" | 6 1/2 oz. |
| 3/8" Pitch |
| |||
|
|
|
|
| 549m/min. |
| 406mm | 190 ml |
| Chain |
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 4 |
|
|
|
|
|
|
Fig.B | Fig.C |
Fig.A
5