Figure 13 — Service Spark Plug

• Reinstall spark plug.

Service Air Cleaner

Your engine will not run properly and may be damaged if you run it using a dirty air filter element.

Check the air filter every use and clean or replace the air filter element every 50 hours of operation or every three months, whichever comes first. Clean or replace more often if operating under dusty or dirty conditions.

To clean or replace air filter element:

Loosen the air cleaner cover screws, remove the air cleaner cover, and remove the element (see page 20).

Wipe clean the inside of the filter housing and cover thoroughly.

Wash the element in a solution of household detergent and warm water, then rinse thoroughly. Or wash in nonflammable or high flash point solvent. Allow the element to dry thoroughly.

Soak the element in clean engine oil and squeeze out the excess oil. Do Not twist. The engine will smoke during initial start-up if too much oil is left in the element.

NOTE: If you need to order a new air filter element, please contact the local dealer.

Reinstall the air cleaner element and the cover. Hand tighten the air cleaner cover screws.

Clean Spark Arrester Screen

The engine muffler is equipped with a removable spark arrester screen. Inspect and clean the screen every

10 hours of operation or every three months, as shown in Figure 14:

Loosen the screw on the muffler and remove the spark arrester screen.

Figure 14 – Service Spark Arrester Screen

Muffler

Spark Arrester

Screen

Spark Arrester

Attachment Screw

Use a brass or stiff-bristle brush to remove carbon deposits from the spark arrester surface.

Inspect the spark arrester for breaks or tears and replace it if necessary.

NOTE: If you need to order a new spark arrester, please contact the local dealer.

• Install the clean screen in the reverse order of removal.

NOTE: If you use your generator on any forest-covered, brush-covered or grass-covered unimproved land, it must have a spark arrester installed. The spark arrester must be maintained in good condition by the owner/operator.

STORAGE INSTRUCTIONS

Transporting and Storage

When transporting the generator, turn the engine switch to “Off” and the fuel valve to “Close”. Keep the generator level to prevent fuel spillage.

WARNING! Contact with a hot engine or exhaust system can cause serious burns or fires. Let the engine cool before transporting or storing the generator.

Take care to not drop or strike the generator when transporting. Do Not place heavy objects on the generator.

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.

12

Image 12
Contents G1000 Table of Contents Safety RulesEquipment Description Wear protective goggles, rubber apron, and rubber gloves Engine ON/OFF Switch Used to stop a running engine Know Your GeneratorContents Before Starting EngineGrounding Generator Operating GeneratorStarting the Engine Connecting Electrical Loads Charging a BatteryOil Alert System Stopping the EngineConnector Plugs Volt DC Accessory JackExtension Cords Volt AC ReceptaclePower Management Dont Overload Your GeneratorCapacity ExampleProduct Specifications General Maintenance RecommendationsGenerator Maintenance Generator SpecificationsEngine Maintenance To Clean the GeneratorClean/Replace Spark Plug Checking Oil LevelService Air Cleaner Clean Spark Arrester ScreenTo clean or replace air filter element Storage InstructionsLong Term Storage Instructions Other Storage TipsTroubleshooting Problem Cause CorrectionWiring Diagram Exploded View and Parts List Main Unit Qty DescriptionCAP, Fuel Exploded View and Parts List Engine Cylinder Block, Cylinder Head Qty DescriptionCrankcase Cover, Crankshaft/Camshaft Qty Description Piston/Rod, Magneto/Flywheel, Air Cleaner Qty Description SET, RING, PSTN, STDCarburetor, Control/Linkages Qty Description Fan Cover, Recoil Starter, Oil Sensor Qty Description Lead Wires, Muffler, Gasket Set Qty Description Tabla DE Contenidos Descripción DEL EquipoAdvertencia Instrucciones DE SeguridadPrecaución Los generadores producen un voltaje muy poderosoConozca SU Generador Bujía cubierta del interiorContenido DEL Empaque Antes DE Darle Arranque AL GeneradorAñadir Aceite de Motor Añadir GasolinaConexion a Tierra DEL Generador Cómo Utilizar SU GeneradorPara Arrancar el Motor Conexion de Cargas Elecricas Detener el MotorAceite Sistema Alerta Procedimiento de Carga de la BateriaEnchufes DE Conexión Cables DE ExtensiónClavija Accesoria de 12 Voltios DC, 8.3 Amperios Receptáculo de 120 Voltios ACNo Sobrecargue EL Generador CapacidadControl de la Energía EjemploEspecificaciones DEL Producto Recomendaciones Mantenimiento GeneralesMantenimiento DEL Generador Especificaciones del GeneradorMantenimiento DEL Motor Para Limpiar el GeneradorVerfique el Nivel de Aceite Cambiar el Aceite del MotorInstrucciones DEL Almacenamiento Mantenimiento del Filtro de AireLimpiar el Tamiz Protector Contra Chispas Transporte y AlmacenamientoOtros Consejos de Almacenamiento Diagnóstico Y Reparación DE Averías Emission Control System Warranty What is CoveredWhat is Not Covered Garantia DEL Sistema DE Control DE Emisiones Sus Obligaciones y Derechos de GarantíaQue Esta Cubierto Que No Esta CubiertoGarantía Limitada Generac Portable Products, LLC Jefferson, Wisconsin U.S.ASnapper Owner Warranty Policy Effective October 1 About your equipment warrantyInstallation and Maintenance Normal wear