Carrier 500 T/R Changing the language, Programming the vehicle ID No. and the customer’s name

Page 11

Changing the language

1.Press the green key and select menu 3.4 with ↑ ,↓ .

2.Press again the green key to edit (enter) the menu 3.4.

3.Select the desired language with < …> and validate with the green key.

4.Press the red key to return to the normal display.

Programming the vehicle ID No. and the customer’s name

1.Press and hold for two seconds the green key to get into the configuration menu.

2.Enter the PIN code 1111 by pressing the blue key four times.

3.Select Menu 10.3. (Vehicle ID) and press the green key to enter the edit mode.

4.Now enter the vehicle ID No. by using the 4 Keys (↑ ,↓ next character from list / < , > one character to the left or to the right).

5.To confirm the input press the green < and red > keys together.

6.Select Menu 10.4 to enter the customer name (Header text). Operation is similar to vehicle ID.

7.Press the Red Key to return to the normal display

2.6Final testing Standard Installation

The next points are subject to a final check after every installation:

- Power supply

The supplied power voltage is between 10V and 36V DC and protected with the 3A floating fuse. The power supply must be sufficient to offer 25W (can be checked by attempting printing).

- Display/keyboard

The display background light must switch on after pressing any key (except if using the permanent background light function) and an acoustic signal audible. The display shows the actual temperatures of the activated temperature inputs.

- Temperature sensors

After approx. 5 minutes the temperature must be correctly displayed. A value of –40°F (-40°C) indicates the possibility of a non connected sensor or a cable failure. A value of +122°F (+50°C) indicates a possible short between the connector pins.

2.7Supplementary installation

The next points are subject to a check if applicable:

- Printer

Test the printer by printing any ticket.

- Digital inputs

For each activated status input, a small box appears in the top right hand of the display (pre-defined symbol, indicating that the corresponding input has been activated). When the status of the input changes to ‘active’ the box will change into a symbol suiting to the function of this input. (for example Refrigeration ON shows ‘’).

- Alarm signal

The internal alarm signal (persistent buzzer) sounds as soon a pre-programmed temperature limit has been exceeded. At the same time an external signal is activated on the 5-pin connector block and the corresponding temperature input on the display will flash. The internal signal buzzer can be switched of by pressing the yellow (Alarm) key. The external signal and the flashing display will only stop after the temperature is back within the programmed limits.

Page 11

62-61138-20 (02/03)

Image 11
Contents Installation USER’S Manual DataCOLD 500 T DataCOLD 500 RTable of Contents Green Edit General descriptionBlue YellowPositioning Connections InstallationPrinter Optional junction box MountingDataCOLD R-Version CON4 Optional Mounting kitDataCOLD T-Version ConnectorsPower supply Is not Used for More than TEN 10 Days Display background lighting preferable for the R-Version Alarm outputsWiring ConfigurationAlarm signal Final testing Standard InstallationTemperature sensors Supplementary installationUser menus Page Day end time Alarm menuDay start time Date setting User settingsTime setting Summer / wint time settingBuzzer frequency setting Display back light settingKeyboard back light setting Buzzer volume settingReturn air Menu 5 Temperature inputs settingsParameter menu T1 Input On/offT3 Input On/off. Menu structure as T4 Input Compartment On/off Menu 6 Digital inputs settingsDigital inputs setting On/off Menu 7 Compartment settingsDelivery ticket settings Menu Alarm settingsAlarm group On/off Menu 9 Printer settings10.2 Sample rate Minutes Menu 10 General settingsTemperature units C Menu 11 Communication settings11.2 COM2 RS-232 port setting Part Number Designation Accessories and spare parts62-61138-20 02/03 Enclosure a Enclosure B Replace paper roll Printer settings Enclosure C Factory settingsTemperature inputs Factory setting Compartment settingsEnter Pincode Enclosure D Failure codes & Set correction factor procedureDigital Inputs configuration example Enclosure E Wiring diagrams= GND = RXD = TXD = CTS