Technical data

 

a)

Technical specification:

 

 

 

 

 

Operating voltage :

 

10-36 Volts DC, protected against alternator load shedding.

Power consumption:

 

Nominal 0.6W, max. 25W (while printing)

Temperature :

 

-22°F to +158°F (-30°C / +70°C) be in operation, -40°F to +185°F (-40°C /

 

 

 

 

+85°C) while in storage

Humidity :

 

 

97% relative humidity at 77°F (25°C)

Memory size :

 

512kB, minimum 1 year with 4 sensors and logging interval of 15 minutes.

Inputs :

 

 

- 4 x temperature for Carrier sensors. Measurement range –40°F to +122°F

 

 

 

 

(-40°C to +50°C)

 

 

 

 

- 1 x Digital for display background light, active >5V

 

 

 

 

- 4 x Digital, closed circuit

Outputs :

 

 

2 x open input, switched to ground and current limited to 1A.

Data ports :

 

 

- Infra-red for data transmission and service/parameter programming

 

 

 

 

- RS-232 5 Pins connector for external devices

b)

Ventilation

 

 

 

No special requirements. DataCold 500 T/R recorders are designed for use in an automotive environment.

c) IP rating

DataCOLD T, Trailer version for outside mounting, IP65

DataCOLD R, Cab version for mounting in the cab, IP22

d) Dimensions ( W x H x D)

DataCOLD T, 9.65 x 7.95 x 4.3 inches (245 x 202 x 110mm)

DataCOLD R, 7.4 x 2.3 x 5.7 inches (188 x 58 x 145mm)

e) Maintenance:

Use for cleaning a moistened duster, without alcohol or other volatile cleaning products.

f)Circuit protection

For protection a 3A (T) floating fuse must be fitted in the positive (+ 12/24V ) power line as close as possible to the power connection. (contained in installation kit).

g) Battery

Units contains a Lithium-Battery, please remove before discarding.

h) Certification

DataCOLD 500 T/R recorders are tested and approved to the European EN12830 specification meeting the objectives of directives 92/1/EU and 93/43/EU and "e" mark approved following directive 95/54/CE.

Page 25

62-61138-20 (02/03)

Image 25
Contents Installation USER’S Manual DataCOLD 500 T DataCOLD 500 RTable of Contents Blue General descriptionYellow Green EditPrinter InstallationPositioning Connections DataCOLD R-Version MountingOptional junction box CON4 Optional Mounting kitPower supply ConnectorsDataCOLD T-Version Is not Used for More than TEN 10 Days Wiring Alarm outputsConfiguration Display background lighting preferable for the R-VersionTemperature sensors Final testing Standard InstallationSupplementary installation Alarm signalUser menus Page Day start time Alarm menuDay end time Time setting User settingsSummer / wint time setting Date settingKeyboard back light setting Display back light settingBuzzer volume setting Buzzer frequency settingParameter menu Menu 5 Temperature inputs settingsT1 Input On/off Return airT3 Input On/off. Menu structure as T4 Input Digital inputs setting On/off Menu 6 Digital inputs settingsMenu 7 Compartment settings Compartment On/offAlarm group On/off Menu Alarm settingsMenu 9 Printer settings Delivery ticket settingsTemperature units C Menu 10 General settingsMenu 11 Communication settings 10.2 Sample rate Minutes11.2 COM2 RS-232 port setting Part Number Designation Accessories and spare parts62-61138-20 02/03 Enclosure a Enclosure B Replace paper roll Temperature inputs Factory setting Enclosure C Factory settingsCompartment settings Printer settingsEnter Pincode Enclosure D Failure codes & Set correction factor procedureDigital Inputs configuration example Enclosure E Wiring diagrams= GND = RXD = TXD = CTS