DataCOLD T-Version

The T-Version has been designed for outside mounting directly on the body. Usually it is fixed under the refrigeration unit on the front side of the body, where it is easily accessible. For fixing proceed as follows: First hold the box in the desired position and mark the mounting holes. Next step is to drill the holes so that the rubber sleeves fit in exactly and the box can be screwed on.

Cables should be installed via watertight cable glands. This avoids moisture penetration into the box. For each cable a separate gland should be used, unless you use a gland especially designed for more cables.

1.Mark the four holes at the front of body in an easily accessible location (usually underneath the refrigeration unit to the right or left hand side). Then drill holes with a 25/64 inch (10mm) drill.

2.Insert the four rubber mounting nuts. Mount recorder using the four screws and washers provided (note metal washer to be located on the outside of the mounting lug fixed to the box). Ensure screws are screwed in tight.

3.Drill hole large enough at suitable location through bulkhead to pass the temperature sensors through.

4.Connect power cable directly to the battery as described in the connection and wiring diagram section. Recorder will start recording automatically.

5.Ensure all holes drilled through body are sealed with a suitable silicone sealer.

2.3Connectors

Since both versions are provided with identical PCB’S, the connections are the same for both versions. On the back of the recorder you will find four connector blocks . Each of them are described in detail in the next paragraphs.

Connector CON 1 (Power supply and outputs)

- Power supply

Connect power supply on pin 1 (+) and pin 2 (-) directly to the battery. The recorder is suitable for a voltage between 10 - 36 Volt DC. Power consumption when printing is 25W.

Page 8

62-61138-20 (02/03)

Image 8
Contents Installation USER’S Manual DataCOLD 500 R DataCOLD 500 TTable of Contents General description BlueYellow Green EditPositioning Connections InstallationPrinter Optional junction box MountingDataCOLD R-Version Optional Mounting kit CON4DataCOLD T-Version ConnectorsPower supply Is not Used for More than TEN 10 Days Alarm outputs WiringConfiguration Display background lighting preferable for the R-VersionFinal testing Standard Installation Temperature sensorsSupplementary installation Alarm signalUser menus Page Day end time Alarm menuDay start time User settings Time settingSummer / wint time setting Date settingDisplay back light setting Keyboard back light settingBuzzer volume setting Buzzer frequency settingMenu 5 Temperature inputs settings Parameter menuT1 Input On/off Return airT3 Input On/off. Menu structure as T4 Input Menu 6 Digital inputs settings Digital inputs setting On/offMenu 7 Compartment settings Compartment On/offMenu Alarm settings Alarm group On/offMenu 9 Printer settings Delivery ticket settingsMenu 10 General settings Temperature units CMenu 11 Communication settings 10.2 Sample rate Minutes11.2 COM2 RS-232 port setting Accessories and spare parts Part Number Designation62-61138-20 02/03 Enclosure a Enclosure B Replace paper roll Enclosure C Factory settings Temperature inputs Factory settingCompartment settings Printer settingsEnclosure D Failure codes & Set correction factor procedure Enter PincodeEnclosure E Wiring diagrams Digital Inputs configuration example= GND = RXD = TXD = CTS